Release date 22.06.2018

B2.2 Install & Operation Manual

Model Overview

Introduction

A range of compact water dispensers, available as a Reservoir (gravity fed) system and a Direct Chill system:

• Reservoir Chilled & Ambient
• Reservoir Chilled & Hot
• Direct Chill Cold & Ambient
• Direct Chill Cold & Hot

The b2 model is available as countertop and floor standing in three colours.

All Models
All models are self-contained machines with robust steel chassis and attractively injection moulded plastic front and top panels. For floorstanding models there is sufficient space internally for most filters. For countertop models any filters would need to be fitted externally. An IEC Power Lead is supplied for connection to the IEC socket found on the rear of all models (An additional Schuko type is supplied for the
European market).

Chilled
Water is fed into the insulated cold tank under mains pressure. We strongly recommend a Pressure Reducing Valve is fitted to all supplies to regulate the
pressure to 3.5 bar/355 KPat. The cold tank is chilled via the evaporation coil of the capillary controlled
refrigeration compression system. The cold temperature is thermostatically controlled via the adjustment screw on the cold thermostat. This is factory set and is not necessary to adjust in most cases (see Controls).

Ambient
Water bypasses the cold tank for the ambient dispense option in the case of direct chill models, for reservoir models water is fed down through the baffle
plate located inside the cold tank.

Hot
Hot water is provided by a hot water tank with an external heating element. Water is supplied directly into the tank under gravity fed pressure, and when full hot water is dispensed by displacement. The water flow is controlled by either a solenoid valve (direct chill models) or by a tap (reservoir models).

Direct Chill
Borg & Overström Direct Chill utilises innovative technology to chill water instantly. We recommend this system for more demanding environments because of its optimum dispense performance and unrivalled hygienic qualities. Superior to the gravity
fed Reservoir system, Direct Chill technology chills water on demand for the ultimate drinking experience.

Controls

Cold Thermostat

controls image 1
This shows the correct and factory default set point.  Although adjustment is possible (clockwise reduces the temperature and anti-clockwise increases the 
water temperature), this correct default setting is to ensure optimum performance and reliability. Unauthorised alternative settings could cause technical issues and invalidate the warranty.

Chilled
On/Off Switch: at rear of machine, switches cooling operation on/off.

Cold Thermostat: At rear of machine.

NOTE: on a Direct Chill model this is located inside.

Cold Tap: Push tap lever down.

Reservoir Models – Cold & Ambient only:

Green LED: Cooling operation is switched on.

Yellow LED: Colour shows compresor is in operation.

Ambient
Ambient Tap: Push tap lever down.

Hot
On/Off Switch: The hot water heating mode

is controlled by a switch on the back of the unit, next to the cooling mode switch. This switch is labelled “Hot”.
Hot Thermostat: regulated by a pre-set, nonadjustable sensor on the tank.

Hot Tap: Lift red safety tab and push down lever.

Red LED (on hot water icon): Colours to show heating mode is enabled.

Reservoir Models – Cold & Hot only:

Green LED: Cooling operation is switched on.

Yellow LED: Hot operation is switched on.

Red LED: Heater element active according to thermostatic demand.

10A Fuse: On rear of machine, integral with
IEC socket.

Components

Major Components & Water Connection - Reservoir variant

Major-Components-and-Water-Connection-Reservoir-variant

Major Components & Water Connection - Direct Chill variant

Major-Components-and-Water-Connection-Direct-Chill-variant

Operation

Water Connection & Operation

1-Water-Connection-and-Operation

On reservoir models remove the Carbon bag from the cold tank. Connect and turn on the water supply. Then connect the power supply.

2-Water-Connection-and-Operation

Dispense from all options (to confirm water supply).

3-Water-Connection-and-Operation

Turn on the cold switch (located at the rear on the unit) to begin the chilling process. Turn on the hot switch (also located at the rear on the unit) to activate the heating element.

4-Water-Connection-and-Operation

The relevant indicator lights will be lit.

5-Water-Connection-and-Operation

Flush through 10 litres of water before use.

6-Water-Connection-and-Operation

Chilled & Ambient:
When the Green LED is on the cooling circuit is activated. When the Yellow LED is on the
compressor is operating.

Chilled & Hot:
When the Green LED is on the cooling circuit is activated. When the Yellow LED is on heating circuit is activated. When the Red LED is on the heating element is activated.

7-Water-Connection-and-Operation

Allow up to 1 hour for the water to reach its minimum
temperature.

8-Water-Connection-and-Operation

The temperature of the chilledwater can be set from 4c to 10c. When the chilling LED is off the set temperature has been reached. This can take up to one hour.

Functions & Controls

Functions-and-Controls

General Safety

General-Safety

Maintenance

NOTE: All maintenance opertaions must be carried out with the dispenser switched off.

Isolation & Removal

1-Isolation-and-Removal

Please make sure the machine is completely disconnected from the electrical supply before carrying out any maintenance work.

2-Isolation-and-Removal

Turn off the water supply.

3-Isolation-and-Removal

To drain cold and ambient units, simply push each tap lever untill no water dispense. For cold and hot dispensers push the cold dispense until no water dispenses and then remove the drain bung to empty the hot water tank.

Warning

Caution: hot water may spill from the hot tank during this operation.

Sanitisation Guide

NOTE: Before beginning the sanitation process please ensure that water is turned off at the mains and refer to the MSDS document for further information. Use bioguard hand gel and ensure gloves are worn.

For reservoir variants always ensure that the hot water outlet is plugged before beginning this procedure (use gloves). Never push the hot water button during the sanitisation procedure.

1-Reservoir-Variant

Remove the top panel by undoing 2x screws at the rear
of the dispenser.

2-Reservoir-Variant

Remove the polystyrene lid. Gently lift the plastic lid from the tank, taking care not to disconnect the plumbing.

3-Reservoir-Variant

Dispense chilled water until the baffle plate is accessible.

4-Reservoir-Variant

Insert the Hot tank sanitisation plug into the centre of the hot tank, press down firmly. Refit the plastic lid to the tank.

Follow steps 1-12below.
Once the sanitisation procedure is complete repeat step 3 and reverse step 4 above, then remove the Hot tank sanitisation plug and replace the plastic lid firmly on the tank, then replace the polystyrene lid and top panel. Ensuring the screws are done up before leaving.

1-Sanitisation-Guide

Briefly press chilled/ambient dispense buttons to release internal water pressure from the machine.

2-Sanitisation-Guide

Remove the existing filter.

3-Sanitisation-Guide

Add 25 ml of Sterizen® 30 Internal Water Cooler Sanitiser fluid to a clean and empty service filter cartridge.

4-Sanitisation-Guide

Connect to machine.

5-Sanitisation-Guide

Turn on incoming water, allow service cartridge/doser to fill.

6-Sanitisation-Guide

Dispense water using the chilled button until the water
appears pink. Briefly press the ambient button too.

7-Sanitisation-Guide

Leave the solution inside machine for sanitisation
(minimum 5 minutes) while thoroughly cleaning the
machine externally, pay particular attention to the dispense faucet and buttons.

8-Sanitisation-Guide

Remember to include the drip tray. If a Waste Overflow System is fitted, empty this and flush through with a small amount of sanitisation fluid if needed.

9-Sanitisation-Guide

When the external cleaning (minimum 5 minutes) is completed, flush the machine using the chilled button with clean water until the dispense water runs clear. Repeat briefly with the ambient button.

10-Sanitisation-Guide

Turn off water and remove the service filter. Retain service filter for reuse.

11-Sanitisation-Guide

Fit new filter. Turn on incoming water supply.

12-Sanitisation-Guide

Pre-flush the new filter to waste using the ambient button until the water appears clear and is free of air. Flush through a small amount of water to check all functions.

Advanced Troubleshooting

Fault Diagnosis: No Water Dispenses

Problem/ReportPossible CauseSuggested Action
From Ambient TapWater Supply turned off (and tank empty)Check all that taps/valves/ filters
on the incoming supply are fitted
and are turned on.
“Waterblock” tripped off (and tank
empty).
Reset “Waterblock” (and check for
any leaks).
“Leak detector” (if fitted) tripped off
(and tank empty).
Disconnect the power and water
supply, reset the machine (check
for leaks).
Tap not working (and tank full). Dismantle and check the tap,completely replacing the tap or just the washer as necessary
Reservoir Float Valve jammed (and tank empty).Replace/adjust postion /repair as needed
Blocked tank outlets/pipes.Check and unblock or replace as
needed.
From Cold TapFirstly all as for Ambient TapCarry out checks and actions as for Ambient Tap
Chiller tank frozen – Thermostat set too low.Thaw out the machine and increase cold water temperature.
Chiller tank Frozen - Thermostat not
working.
Thaw out the machine and check
thermostat. Replace Cold Water thermostat as needed.
From Hot TapFirstly all as for Ambient Tap.Carry out checks and actions as for Ambient Tap.
Airlock in dispense pipe work.Unblock/replace hot water pipe and hot vent pipe. (Check water level showing in hot vent pipe).
Tank filled with limescale.Replace tank.

Fault Diagnosis: Water Dispenses but not Correct Temperature

Problem/ReportPossible CauseSuggested Action
Ambient Water too WarmLow usage and/or heat from compressor influencing stored
water.
Check tank insulation and/or advise customer.
High usage and/or water supply pipe in warm ducting.Advise customer.
Cold Water not ColdCooling switched off.Check switch positions as necessary.
Compressor runs and switching off (cool/warm to touch) - Thermostat
set too high.
Decrease cold thermostat set point.
Thermostat not working.Check/replace thermostat.
Compressor runs but not switching off (hot to touch).Please contact technical support.
Refrigeration problem Please contact technical support.
Compressor not running at all.Please contact technical support.
No electricity power supply.Check the Power cord is connected and live, and the machine is switched on.
Compressor only hums slightly/ briefly.Check and replace relays.
Relays loose.Check and refit relays.
Compressor not working.Please contact technical support.
Cold tank Baffle Plate not connected.Refit Baffle Plate.
Hot Water not HotHot water mode switched offSwitch on hot water mode (status LED should show).
Heating operation tripped off.Reset overheat button on hot tank.
Break in supply wiring to control circuit.Locate break and repair.
Hot water demand too high.Advise user/s.
Main reheat element not working (Red LED on all the time).Check supply voltage and current
to hot thermostat and replace accordingly
Hot tank heavily scaled (signs of scale in top of tank, loud boiling noises etc).Carry out thorough descale or replace hot tank.
Break in supply wiring to main element.Locate break and repair.

Fault Diagnosis: Water Leaks

Problem/ReportPossible CauseSuggested Action
Water lying on top edge of lower door panel and/or bottom of the machine.Overflowing Drip Tray waste container.Empty Waste Container and check
drainpipe is not blocked.
Water lying in bottom of machineLeak in supply inlet pipe work and/ or filter.Locate and repair accordingly.
Leak from machine water pipes and/or fittings.Locate and repair accordingly.
Overflowing cold tank.Reservoir Variant: float valve not connected or malfunctioning -
replace if necessary.
Direct Chill Variant: float valve or internal cold tank water fittings not connected or malfunctioning -
replace if necessary.
Water pressure too high.Check pressure and fit pressure reducing valve if needed.
Jammed float valve. Check and repair float valve.
Split Float Valve washer.Replace washer.
Overflowing cold tank (Hot Tank exclusively sealed).Replace hot tank.
Hot Tank thermistor probe not working.Check and replace probe (Conversion Kit recommended).
Control Board not working.Check and replace main control board (Conversion Kit
recommended).
Condensation from tank or cold water pipe.Check insulation and repair/replace accordingly.

Fault Diagnosis: Miscellaneous

Problem/ReportPossible CauseSuggested Action
No LED control lights No eletricity to Machine.Check power supply and reconnect as necessary (Also check out other symptoms as described separately).
Control PCB not working (Machine
working normally otherwise).
Check/replace PCB.
Machine Shakes on Start-upCompressor Starting.No action needed. This is quite normal.
Level Surface.
Uneven Surface.Level up machine using adjustable feet.
Missing Fixings.Replace missing fixings.
Tripping out Electricity SupplyMachine in high humidity environment.Discuss possible repositioning with customer.
Electrical circuitry faults.Test, identify and address accordingly. See Electrical Diagrams.
Please contact technical support.

Exploded Diagrams

Chilled & Ambient – Reservoir

Part number:Description: 
123818b2 NG Top Cover Panel BlackView in store
135729b2/b3 Floorstanding Reservoir Insulation TopView in store
133410Clip on Tank lid AssemblyView in store
1316471/4" Push Fit ElbowView in store
132457Reservoir Float Valve (Lid type) - AssemblyView in store
852108IEC Power Cordset - SwissView in store
172152IEC Power Cordset - UKView in store
172148IEC Power Cordset - Shucko/EUROView in store
172144IEC Power Cordset - DanishView in store
135727b2/b3 Floorstanding Reservoir Insulation SleeveView in store
133419Reservoir Baffle PlateView in store
4620131/4" White Tubing per mtrView in store
131425Insert for Cold TankView in store
134583Cold Water PipeView in store
174231Electric Rocker SwitchView in store
173251b2/b3 Cold ThermostatView in store
1316421/4" PF Inlet Elbow Bulkhead ConnectorView in store
1316411/4" PF Inlet Straight Bulkhead ConnectorView in store
172163IEC Fused SocketView in store
120909b2 NG Front Panel - BlackView in store
120908b2 NG Front Panel - WhiteView in store
120907b2 NG Front Panel - SilverView in store
142121b2 NG Cold TapView in store
121956b2/b3 Floorstanding Right Side PanelView in store
134582Ambient Water PipeView in store
142122b2 NG Ambient TapView in store
171201b2 CA Circuit BoardView in store
126821b2 NG Tap Cover Panel - BlackView in store
191145b2 NG Reservoir Chilled & Ambient Control Panel LabelView in store
184622Magnetic door catch including screwView in store
125823b2 NG Drip Tray Set - BlackView in store
121859Side HandleView in store
184601b2/b3 Floorstanding Filter BracketView in store
120972b2 NG Door Panel - SilverView in store
120973b2 NG Door Panel - WhiteView in store
120974b2 NG Door Panel - BlackView in store
121955b2/b3 Floorstanding Left Side PanelView in store
124952b3 Floorstanding Base PanelView in store
184531b2/b3 Floorstanding Adjustable FootView in store

Chilled & Hot - Reservoir

Part number:Description: 
123818b2 NG Top Cover Panel BlackView in store
135729b2/b3 Floorstanding Reservoir Insulation TopView in store
133410Clip on Tank lid AssemblyView in store
1316471/4" Push Fit ElbowView in store
132457Reservoir Float Valve (Lid type) - AssemblyView in store
135727b2/b3 Floorstanding Reservoir Insulation SleeveView in store
133419Reservoir Baffle PlateView in store
131425Insert for Cold TankView in store
4620131/4" White Tubing per mtrView in store
134583Cold Water PipeView in store
174231Electric Rocker SwitchView in store
172163IEC Fused SocketView in store
173251b2/b3 Cold ThermostatView in store
121859Side HandleView in store
121955b2/b3 Floorstanding Left Side PanelView in store
142123b2 NG Hot TapView in store
142121b2 NG Cold TapView in store
184601b2/b3 Floorstanding Filter BracketView in store
124952b3 Floorstanding Base PanelView in store
184531b2/b3 Floorstanding Adjustable FootView in store
1316411/4" PF Inlet Straight Bulkhead ConnectorView in store
1316421/4" PF Inlet Elbow Bulkhead ConnectorView in store
121956b2/b3 Floorstanding Right Side PanelView in store
120907b2 NG Front Panel - SilverView in store
120908b2 NG Front Panel - WhiteView in store
120909b2 NG Front Panel - BlackView in store
120974b2 NG Door Panel - BlackView in store
120973b2 NG Door Panel - WhiteView in store
120972b2 NG Door Panel - SilverView in store
125823b2 NG Drip Tray Set - BlackView in store
171202b2 CH Circuit BoardView in store
126821b2 NG Tap Cover Panel - BlackView in store
1316611/4" Equal Elbow Stem onlyView in store
154521Hot Vent Pipe - 300mmView in store
154524Hot Tank Feed PipeView in store
154523Hot Water Pipe/DC Tank PipeView in store
17326590C/105C Hot Tank Sensor SetView in store
166880b2/b3 Hot Tank (New) c/w HB & 90/105 TC SetView in store
131423b2 Countertop Drain BungView in store
172144IEC Power Cordset - DanishView in store
172148IEC Power Cordset - Shucko/EUROView in store
172152IEC Power Cordset - UKView in store
852108IEC Power Cordset - SwissView in store
191146b2 NG Reservoir Chilled & Hot Control Panel LabelView in store
184622Magnetic door catch including screwView in store

Chilled & Ambient - Direct Chill

Part number:Description: 
123818B2 NG Top Cover Panel BlackView in store
133416DC Cold Tank LidView in store
135721DC Cold Tank Lid insulationView in store
1316421/4" PF Inlet Elbow Bulkhead ConnectorView in store
4620131/4" White Tubing per mtrView in store
133418B2 Direct Chill Header Tank LidView in store
852108IEC Power Cordset - SwissView in store
172152IEC Power Cordset - UKView in store
172148IEC Power Cordset - Shucko/EUROView in store
172144IEC Power Cordset - DanishView in store
174310Direct chill PumpView in store
133415DC Cold Tank Inner LidView in store
132456Reservoir Float Valve (Side Type) - AssemblyView in store
1314221/4" Inlet Connector Back NutView in store
134601DC Coil for Twin Tank ModelsView in store
1316471/4" Push Fit ElbowView in store
133414B2 Direct Chill Header TankView in store
4620131/4" White Tubing per mtrView in store
174231Electric Rocker SwitchView in store
172163IEC Fused SocketView in store
4620131/4" White Tubing per mtrView in store
1316431/4" PF Stem ElbowView in store
4620131/4" White Tubing per mtrView in store
1316441/4" Push-Fit 4 way JointView in store
1316421/4" PF Inlet Elbow Bulkhead ConnectorView in store
1316411/4" PF Inlet Straight Bulkhead ConnectorView in store
120909B2 NG Front Panel - BlackView in store
120908B2 NG Front Panel - WhiteView in store
120907B2 NG Front Panel - SilverView in store
194121Grit FilterView in store
173251B2/B3 Cold ThermostatView in store
131424DC Tank Pipe ConnectorView in store
154523Hot Water Pipe/DC Tank PipeView in store
134581DC Tank PipeView in store
173249HP1/4PFx1/2STS230 Solenoid ValveView in store
121956B2/B3 Floorstanding Right Side PanelView in store
171204B2 CA DC Main Control BoardView in store
126822B2 NG DC Tap Cover Panel - BlackView in store
191147B2 NG Direct Chill Chilled & Ambient Control Panel LabelView in store
151544B2/B3 Floorstanding Drain BungView in store
184415Grommet for B2 NG DCView in store
121859Side HandleView in store
121955B2/B3 Floorstanding Left Side PanelView in store
184625Solenoid Valve Bracket for b2View in store
133512B2 DC Faucet (Light Grey w/o vent)View in store
184622Magnetic door catch including screwView in store
184622Magnetic door catch including screwView in store
120972B2 NG Door Panel - SilverView in store
120973B2 NG Door Panel - WhiteView in store
120974B2 NG Door Panel - BlackView in store
184601B2/B3 Floorstanding Filter BracketView in store
124952B3 Floorstanding Base PanelView in store
184531B2/B3 Floorstanding Adjustable FootView in store

Chilled & Hot - Direct Chill

Part number:Description: 
123818b2 NG Top Cover Panel BlackView in store
133416DC Cold Tank LidView in store
135721DC Cold Tank Lid insulationView in store
1316421/4" PF Inlet Elbow Bulkhead ConnectorView in store
4620131/4" White Tubing per mtrView in store
852108IEC Power Cordset - SwissView in store
172152IEC Power Cordset - UKView in store
172148IEC Power Cordset - Shucko/EUROView in store
172144IEC Power Cordset - DanishView in store
174310Direct chill PumpView in store
133415DC Cold Tank Inner LidView in store
1314221/4" Inlet Connector Back NutView in store
134601DC Coil for Twin Tank ModelsView in store
133418b2 Direct Chill Header Tank LidView in store
131646Air Vent Elbow for Clip-on Tank LidView in store
132456Reservoir Float Valve (Side Type) - AssemblyView in store
154551L-shape Silicon TubeView in store
174231Electric Rocker SwitchView in store
154521Hot Vent Pipe - 300mmView in store
1316491/4" Push Fit TeeView in store
133414b2 Direct Chill Header TankView in store
1316421/4" PF Inlet Elbow Bulkhead ConnectorView in store
1316411/4" PF Inlet Straight Bulkhead ConnectorView in store
174231Electric Rocker SwitchView in store
1316431/4" PF Stem ElbowView in store
173251b2/b3 Cold ThermostatView in store
120909b2 NG Front Panel - BlackView in store
120908b2 NG Front Panel - WhiteView in store
120907b2 NG Front Panel - SilverView in store
172163IEC Fused SocketView in store
1316431/4" PF Stem ElbowView in store
194121Grit FilterView in store
4620131/4" White Tubing per mtrView in store
121956b2/b3 Floorstanding Right Side PanelView in store
173246LP1/4PFx1/2STS230 Solenoid ValveView in store
131424DC Tank Pipe ConnectorView in store
171205b2 CH DC Main Control BoardView in store
126822b2 NG DC Tap Cover Panel - BlackView in store
191148b2 NG Direct Chill Chilled & Hot Control Panel LabelView in store
154523Hot Water Pipe/DC Tank PipeView in store
134581DC Tank PipeView in store
121859Side HandleView in store
166880b2/b3 Hot Tank (New) c/w HB & 90/105 TC SetView in store
173249HP1/4PFx1/2STS230 Solenoid ValveView in store
184625Solenoid Valve Bracket for b2View in store
133512b2 DC Faucet (Light Grey w/o vent)View in store
125823b2 NG Drip Tray Set - BlackView in store
154536Hot Tank Silicon Feed PipeView in store
184622Magnetic door catch including screwView in store
17326590C/105C Hot Tank Sensor SetView in store
121955b2/b3 Floorstanding Left Side PanelView in store
131423b2 Countertop Drain BungView in store
120972b2 NG Door Panel - SilverView in store
120973b2 NG Door Panel - WhiteView in store
120974b2 NG Door Panel - BlackView in store
184601b2/b3 Floorstanding Filter BracketView in store
124952b3 Floorstanding Base PanelView in store
184531b2/b3 Floorstanding Adjustable FootView in store

Technical Information

Chilled & Ambient Electrical Circuit Diagram - Reservoir Variant

Chilled & Hot Electrical Circuit Diagram - Reservoir Variant

Chilled & Ambient Electrical Circuit Diagram - Direct Chill Variant

Chilled & Hot Electrical Circuit Diagram - Direct Chill Variant

Chilled & Ambient Water Pathway Diagram - Reservoir Variant

Chilled & Hot Water Pathway Diagram - Reservoir Variant

Chilled & Ambient Water Pathway Diagram - Direct Chill Variant

Chilled & Hot Water Pathway Diagram - Direct Chill Variant

Specification

COOLING SYSTEMAll ModelsHigh efficiency compression system with capillary control. Premium quality long life hermetic compressor. External
condenser. Environmentally friendly R134A refrigerant.
Reservoir - Chilled &
Ambient
High volume 3.5 litre stainless steel gravity fed cold tank for optimum water capacity on demand. Insulated tank for energy conservation. Large volume output. Thermostatically
controlled chilled water temperature (range down to 2°C
minimum).
Direct Chill - Chilled &
Ambient
Sealed Direct Chill Ice bank tank for optimum water
capacity on demand and hygiene. Low sanitisation and
maintenance. Insulated tank for energy conservation.
Large volume output via electronic solenoid valves.
Thermostatically controlled chilled water temperature (range down to 2°C minimum).
HEATING SYSTEMReservoir - Chilled
& Hot
High volume 3.5 litre stainless steel gravity fed cold tank for optimum water capacity on demand and hygiene with low sanitisation and maintenance requirement.
Thermostatically controlled chilled water temperature (range down to 2°C minimum). 1.7lt stainless steel hot water tank with thermostatic temperature control (90°C max). Insulated tanks for energy conservation.
Direct Chill - Chilled & HotSealed Direct Chill Ice bank tank for optimum water capacity on demand and hygiene, with low sanitisation and maintenance requirement. Output via electronic solenoid valves. Thermostatically controlled chilled water temperature (range down to 2°C minimum). 1.7lt stainless steel hot water tank with thermostatic temperature control
(90°C max). Insulated tanks for energy conservation.
COLD TEMPRATURE2°C to 11°C
HOT TEMPRATURE90°C Max
THROUGHPUT PER HOUR 22 litres cold 85°C
DISPENSEReservoir variants have a manual tap system, and Direct
Chill Variants have a light touch sensitive control panel.
MAXIMUM RUNNING POWER CONSUMPTIONChilled & Ambient100 watt
Chilled & Hot535 watt
POWER SUPPLYIEC power socket.
WATER CONNECTION1/4 inch quick connection.
COUNTERTOP DIMENSIONS(w x d x h) 325 x 365 x 475mm
FLOORSTANDING
DIMENSIONS
(w x d x h) 325 x 365 x 1060mm
COUNTERTOP WEIGHTSReservoir Chilled & Ambient13.4kg
Reservoir Chilled & Hot14.0kg
Direct Chill Chilled
& Ambient
14.7kg
FLOORSTANDING WEIGHTSReservoir Chilled
& Ambient
21.2kg
Reservoir Chilled & Hot21.8kg
Direct Chill Chilled
& Ambient
21.5kg
Direct Chill Chilled & Hot22.5kg