Unite, DC15:
Release date 13.05.2018

B5 Install & Operation Manual

Model Overview

Introduction

A range of compact water dispensers, available in four different operational types:
• Chilled & Ambient
• Chilled, Ambient & Sparkling
• Chilled, Ambient & Hot
• Chilled, Hot & Sparkling

All Models
All models are self-contained machineswith robust steel framed cabinets and attractively injection moulded plastic front, side and top panels. There is
sufficient space internally for most filters to be fitted behind the door panel. An IEC Power Lead is supplied for connection to the IEC socket found on
the rear of all models (An additional
Schuko type is supplied for the European
market).
The level control system also incorporates a leak detection device within the cabinet which isolates
the water to the unit in the event of detecting a water leak.

Chilled
The cold temperature is thermostatically controlled via the adjustment screw on the back of the machine. This is factory set and is not necessary to adjust in most cases (see Controls).

Ambient
Water bypasses the cold tank for the ambient dispense option.

Sparkling
Water is chilled as it passes through the coil immediately before dispense or being pumped under pressure into the carbonator which it fitted inside the
same coil. The carbonator is also level controlled and allows the sparkling effect to occur through saturation with CO2.

Hot
The hot water is provided by hot water tank with an integrated heater element. The water is supplied directly into the tank under the pressure as connected
into the back of the unit. The water fills the tank and hot water is dispensed. The water flow is controlled by a solenoid.

Controls

Cold Thermostat

controls image 1
This shows the correct and factory default set point.  Although adjustment is possible (clockwise reduces the temperature and anti-clockwise increases the 
water temperature), this correct default setting is to ensure optimum performance and reliability. Unauthorised alternative settings could cause technical issues and invalidate the warranty.

Chilled
On/Off Switch: at upper rear of machine, switches cooling operation on/off.

Cold Thermostat: at rear of machine.

Cold Button: press to dispense cold water.

Green LED (Top): Colours to show cooling operation is switched on.

Green LED (Bottom): Colours to show when compressor is operating/water is above set point.

10A Fuse: On rear of machine, integral with IEC socket.

Ambient
Ambient Button: Press to dispense ambient water.

Sparkling
Soda: Switches sparkling operation on/off.

Sparkling Button: Press to dispense sparkling water

Yellow LED (bottom RH): Colours to show the sparkling operation is switched on.

Hot
On/Off Switch: The hot water heating mode is controlled by a switch on the back of the unit, next to the cooling mode switch. This switch is labelled “Hot”.

Hot Thermostat: regulated by a pre-set, nonadjustable sensor on the tank.

Hot Button: press to dispense hot water.

Lock Button: toggles on and off the dispense of hot water.

Red LED (on hot water icon): Colours to show heating mode is enabled.

Red LED (marked heating): Colours to show heating element is active according to thermostatic demand.

Storage Cabinet

All models are fitted with a lower storage area.

The door panel is hinged and fastened with magnetic catches. There is a removable cover protecting the machine parts.

Every DC15 is supplied with a level sensor kit, comprising:
• Water container
• Level sensor module

Storage-Cabinet

Installation

Major Components

Major-Components

Water and CO2 Connection

Water-and-CO2-Connection

CO2 Bottle Installation (Sparkling Versions Only

IMPORTANT!

IMPORTANT! ALWAYS ENSURE SECURITY CLIPS ARE USED ON ALL WATER AND CO2 CONNECTIONS.

1-CO2-Bottle-Installation

Attach the regulator to the disposable CO2 bottle, ensuring the regulator is closed.

2-CO2-Bottle-Installation

Connect the assembled CO2 bottle and regulator to the machine using 1/4 inch pipe.

3-CO2-Bottle-Installation

After completing the water installation, turn on the soda power switch and the pump will run. Do not open the regulator valve until the carbonated switch has been turned on.

4-CO2-Bottle-Installation

We recommend between 3.5 – 5 bar. Do not exceed 5 bar pressure.

5-CO2-Bottle-Installation

Flush through approximately 10 litres of water. Check and adjust the CO2 pressure accordingly.

6-CO2-Bottle-Installation

It will be necessary to leave the machine for up to 1 hour for sparkling water to develop, by absorbing the CO2.

Level Sensor Assembly

1-Level-Sensor-Assembly

Check all parts are present.

2-Level-Sensor-Assembly

Locate and connect the drainage tubing into the top of the level sensor connector.

3-Level-Sensor-Assembly

The LED lighting at the base of the faucet will flash slowly for 1 minute. This is also repeated every time a
dispense button is pressed.

4-Level-Sensor-Assembly

Empty the waste container to cancel.

A WARNING TONE WILL SOUND WHEN THE WATER RISES. UPON EMPTYING THE CONTAINER THE WARNING TONE WILL STOP.

Operation

Water Connection & Operation

1-Water-Connection-and-Operation

Connect and turn on the water supply.

2-Water-Connection-and-Operation

Plug in the power supply, cold, hot & sparkling tanks will automatically fill.

3-Water-Connection-and-Operation

Activate the carbonation & hot power switch (if present).

4-Water-Connection-and-Operation

Activate cold power switch.

5-Water-Connection-and-Operation

Flush through 10 litres of water before use.

6-Water-Connection-and-Operation

When the cold water switch is turned on, the cold water and chilling LED will be on.

7-Water-Connection-and-Operation

The temperature of cold water can be set from 4c to 10c.
When the chilling LED is off the set temperature has been reached. This can take up to one hour.

8-Water-Connection-and-Operation

When the heating LED is off the pre-set temperature has been reached. This can take up to 30mins.

Functions & Controls

Functions-and-Controls

General Safety

General-Safety

Maintenance

Isolation & Removal

1-Isolation-and-Removal

Please make sure the machine is completely disconnected from electricity before carrying out any maintenance work.

2-Isolation-and-Removal

Turn off the water supply.

3-Isolation-and-Removal

To drain the Direct Chill tank, remove the caps on the back of the machine. We recommend it is refitted immediately upon draining being completed.

Sanitisation Guide

NOTE: Before beginning the sanitation process please ensure that water is turned off at the mains and refer to the MSDS document for further information. Use bioguard hand gel and ensure gloves are worn.

1-Sanitisation-Guide

Briefly press cold/ambient dispense button to release
internal water pressure from the machine.

2-Sanitisation-Guide

Remove the existing filter.

3-Sanitisation-Guide

Add 25 ml of Sterizen® 30 Internal Water Cooler Sanitiser fluid to a clean and empty service filter cartridge.

4-Sanitisation-Guide

Connect to machine.

5-Sanitisation-Guide

Turn on incoming water, allow service cartridge/doser to fill.

6-Sanitisation-Guide

Dispense water using the cold button until the water appears pink. Briefly press the ambient button too. Repeat with sparkling button if present.

7-Sanitisation-Guide

Leave the solution inside machine for sanitisation to take effect (minimum 5 minutes) while thoroughly cleaning the machine externally, pay particular attention to the dispense faucet and button controls.

8-Sanitisation-Guide

Remember to include the drip tray. Empty the Waste Overflow System and flush through with a small amount of sanitisation fluid if needed.

9-Sanitisation-Guide

When the external cleaning (minimum 5 minutes) is
completed, flush the machine using the cold button with
clean water until the dispense water runs clear. Repeat
briefly with the ambient button (and sparkling button if
present).

10-Sanitisation-Guide

Turn off water and remove the service filter. Retain service filter for reuse.

11-Sanitisation-Guide

Fit new filter. Turn on incoming water supply.

12-Sanitisation-Guide

Pre-flush the new filter to waste using the ambient button (and sparkling button if present) until the water appears clear and is free of air. Flush through a small amount of water to check all functions.

Leak Detection

NOTE: This machine is equipped with a leakage detection device. When leaking is detected, the dispense operation will be cut off automatically. This is indicated by a blue LED flashing at the base of the tap.

To reset:

0-Leak-Detection
1-Leak-Detection

Unplug the machine and remove the protective cover.

2-Leak-Detection

Locate the source of leakage and rectify.

3-Leak-Detection

Locate the detection probe which can be found in the bottom at the rear of the machine. Dry the probes and internal area with a dry cloth.

4-Leak-Detection

Locate the Leak Detector valve.

5-Leak-Detection

Reset the red lever (push it in).

6-Leak-Detection

Reconnect the power to machine and test operation.

Emptying the Carbonation Tank

1-Emptying-the-Carbonation-Tank

Switch off the Carbonation System switch on the back of the unit.

2-Emptying-the-Carbonation-Tank

Press and hold the Sparkling water dispense button until all water is expelled.

3-Emptying-the-Carbonation-Tank

The tank is empty of sparking water when only CO2 is being released.

4-Emptying-the-Carbonation-Tank

Ensure to release the Sparkling water button and take care to avoid releasing excess amounts of CO2 gas.

Advanced Troubleshooting

Fault Diagnosis: No Water Dispenses

Problem/ReportPossible CauseSuggested Action
From Ambient ValveWater Supply turned off.Check all taps/valves/ filters on incoming supply are fitted and are
turned on.
No Electricity/Power Supply.Check power cord is connected and live and machine is switched on.
“Waterblock” tripped off (and tank
empty).
Reset “Waterblock” (refer to
manufacturer’s instructions and
check for any leaks).
Check valve action. Carefully dismantle valve and clean out/
part replace/complete replace as needed.
Solenoid Valve not working.Valve clicking but no water - Check if hole in centre of washer is clear.
Valve not clicking - Check for voltage output from control PCB when operated (Caution-High
Voltage). If not present, check
wiring for continuity and/or replace PCB. If present, check coil/PCB and replace solenoid coil/whole
valve coil/whole valve assembly
complete/PCB as needed.
“Level Sensor” Waste Water Container full (Blue LED will flash
slowly when the button is pressed.
This flashing cycle will repeat for 60 secs following the button being pressed).
Empty the container. (The unit will automatically reset to normal operation.)
Leak detector has disabled dispense operation.Check for internal leakage, ensure
probes are dry and reset.
From Cold ValveFirstly all as for Ambient Tap.Carry out checks and actions as for
ambient tap.
Chiller tank frozen – Thermostat not working correctly.Thaw out and check thermostat. Replace Cold Water thermostat as needed.
Chiller tank Frozen - Tank pump not working.Thaw out and check tank pump. Replace pump and or check
electricity supply to pump present.
Problem/ReportPossible CauseSuggested Action
From All ValvesButton not being pressed enough.Press button firmly.
PCB control not working.Check/replace as necessary.
From Sparkling ValveFirstly as for ambient and cold valve.Carry out the checks and actions as for cold and ambient.
Low or no CO2.Check and replace cylinder as necessary.
Pump not operating.Check carbonator level control system.
Check probes connected/Leads attached. Check power supply to pump.
Carbonator Tank over pressurised with CO2.1. Switch the Sparkling System off.
2. Shut off CO2 supply.
3. Press the Sparkling Water button to release CO2 from carbonator.
4. Switch the Sparkling system on.
5. Check pump operation is
running normally.
6. Wait for the pump to stop running.
7. Re-open CO2 supply.
Pump Feed Solenoid Valve.Check function/condition and repair/replace accordingly.
Carbonation System switched off.Switch on (Switch on back of the machine).
From Hot ValveHot water lock button not being pressed.Press hot water lock button prior to hot water button.
If during first installation:
Ensure that the hot tank has filled. This fills automatically upon first installation – allow 2-3 mins.
Check and follow installation instructions.
If following normal usage: Follow the same guidance as for ‘Ambient’ valve. Carry out checks.
Hot Tank Level Probes
disconnected.
Check and rectify, as necessary.
Hot Tank Level Probes have limescale build-up/damage.Check and clean/replace, as
necessary.
Hot Tank Level Control Failed.Replace Hot Tank Level Control Board.
Hot Tank has excessive limescale build-up.Check & Replace Hot Tank as necessary.
Hot Safety dispense function not working.Check & replace Main Control Board as necessary.
Hot Tank Solenoid (fill solenoid) failed.Check & Replace as necessary.
Hot Water Dispense Pump failed.Check & Replace as necessary.
Hot Water dispense pipe blocked.Check & Replace as necessary.

Fault Diagnosis: Water Dispenses but not Correct Temperature

Problem/ReportPossible CauseSuggested Action
Ambient Water too WarmLow usage and/or fed from water
supply pipe in warm ducting.
Advise user replacing external
causes and solutions.
Cold Water not ColdCooling switched off.Check switch positions.
Compressor runs and switching off
(cool/warm to touch) - Thermostat
set too high.
Decrease Cold Thermostat set point.
Thermostat not working.Check and replace as necessary.
Compressor runs but not switching off.Please contact technical support.
Refrigeration problem.Please contact technical support.
Compressor not running at all.Check and trace voltage path. Check windings resistance.
No electricity power supply.Check the Power cord is connected
and live, and the machine is switched on.
Compressor only hums slightly/ briefly.Check and replace relays.
Relays loose.Check and refit relays.
Compressor not working.Please contact technical support.
DC Tank empty.Check water level and replace level
sensor in fill valve as needed.
Fan not working.Check and replace, as necessary.
Hot Water not HotHot water mode switched off.Switch on hot water mode.
Heating cycle incomplete.Wait for heating LED to stop showing.
Hot water demand too high.Advise user/s.
Hot Thermostat not working. Replace thermostat.
Over heat function active (Heating mode LED not showing while heating mode switch on).Reset switch on overheat temperature sensor.
Hot Water Heater not working. Replace Hot Water Tank.

Fault Diagnosis: Water Leaks

Problem/ReportPossible CauseSuggested Action
Water lying on top edge of lower door panel and/or bottom of cabinet.Overflowing Drip Tray waste container.Empty Waste Container and check
drainpipe is not blocked.
Water lying in bottom of machineLevel Sensors not working.Check operation and
replace if needed.
Leak in supply inlet pipe work and/or filter.Locate and repair accordingly.
Leak from machine water pipe work fittings.Locate and repair accordingly.
Check pressure and fit pressure reducing valve if needed.
DC tank overfilling.Check level control sensor and fill valve function.

Fault Diagnosis: Miscellaneous

Problem/ReportPossible CauseSuggested Action
No LED Control LightsNo electricity to Machine.Check power supply and reconnect as necessary (Also check out other
symptoms as described separately).
Check Fuse in IEC Socket.Replace if necessary.
Control PCB not working (Machine
working normally otherwise).
Check & replace PCB as necessary.
Machine Shakes on Start-up.Compressor Starting.No action needed. This is quite normal.
Level Surface.
Uneven Surface.Level up machine using adjustable feet.
Missing Fixings.Replace missing fixings.
Tripping out Electricity Supply.Machine in high humidity environment.Discuss possible repositioning with customer.
Electrical circuitry faults.Test, identify and address accordingly. See Electrical Diagrams.
Please contact technical support.
No/Inadequate Water Dispenses Low incoming Water pressure.Consider re-plumbing to alternative supply if possible or providing a pressure boost system.
Low/no CO2 Pressure. Check regulator and/or replace cylinder.
Intermittent Water Dispense From
Sparkling Water Valve
Trapped air in pipe work (especially where water pressure is low or after filter change).Hold button on to purge air out. (This could take several minutes where pressure is low).
Use filter function if available.
Button not being pressed enough.Press button firmly N.B. This could be caused by a surrounding cold
environment making the action stiffer.
Control PCB not working. Check & replace as necessary.
Slow but Continuous Water Dispense From Hot Water Valve.Limescale build-up inside Hot Water
Tank/Hot Water Pump/Hot Water
Dispense Pipework.
Replace Hot Water Tank/Hot Water Pump/Hot Water Dispense Pipework, as necessary.
Hot Water Pump not working. Check & replace as necessary.
Intermittent Water Dispense & Hammering NoiseFluctuating mains water pressure situation.Contact Technical Support regarding special replacement
washers available.
Continuous Water DispenseButton jammed on/ not working.Replace Control PCB and or/ button Panel as needed.
Debris blocking hole in diaphragm washer.Dismantle Valve and clean out.
Solenoid valve not working.Check valve and replace if needed.

Exploded Diagrams

Chilled & Ambient

Part number:Description: 
123155Left Top Panel Cover PlateView in store
171244Faucet LED Assembly - 6BView in store
123156Right Top Panel Cover PlateView in store
145015Waste Drain GrillView in store
191171Chilled & Ambient labelView in store
191175Control Button Membrane Under LinerView in store
172144IEC Power Cord set - DanishView in store
121516Side Panel - RightView in store
120515Door Panel (Shell only)View in store
120521Door Panel InfillView in store
173274Leak Detector ProbeView in store
193165Waste Water Container (2 ltr)View in store
173277Leak Detector ModuleView in store
173267Cold ThermostatView in store
1314262-Port Drainage OutletView in store
171241DC Level Control BoardView in store
184565Cup Dispenser Tube SetView in store
171235DCA Main Control BoardView in store
173241Solenoid ValveView in store
194121Grit FilterView in store
1324481/4" PF x 1/4" Stem Single Check ValveView in store
174352FanView in store
184602Inner Front CoverView in store
174323IEC FuseView in store
121515Side Panel - LeftView in store
172231Compressor Relay SetView in store
123154Upper Top PanelView in store
17437724vDC PSUView in store
175363DC PumpView in store
145011DCA/H Faucet AssemblyView in store
193187Waste Water Container (Optional 10ltr)View in store
172148IEC Power Cord set - Schuko/EUROView in store
172152IEC Power Cord set - UKView in store
852108IEC Power Cord set - SwissView in store
171247Faucet LED Assembly - 4B (1404)View in store

Chilled, Ambient & Sparkling

Part number:Description: 
171236DCAS Main Control BoardView in store
171242DCS Level Control BoardView in store
1324481/4" PF x 1/4" Stem Single Check ValveView in store
1314262-Port Drainage OutletView in store
120515Door Panel (Shell only)View in store
120521Door Panel InfillView in store
121515Side Panel - LeftView in store
123155Left Top Panel Cover PlateView in store
123156Right Top Panel Cover PlateView in store
145015Waste Drain GrillView in store
121516Side Panel - RightView in store
171244Faucet LED Assembly - 6BView in store
172144IEC Power Cord set - DanishView in store
173241Solenoid ValveView in store
173267Cold ThermostatView in store
173274Leak Detector ProbeView in store
173277Leak Detector ModuleView in store
174352FanView in store
184565Cup Dispenser Tube SetView in store
174323IEC FuseView in store
193165Waste Water Container (2 ltr)View in store
194121Grit FilterView in store
172231Compressor Relay SetView in store
191173S42 DCAS Control Button MembraneView in store
191175Control Button Membrane Under LinerView in store
184602Inner Front CoverView in store
123154Upper Top PanelView in store
17437724vDC PSUView in store
17438548vDC Carbonation Pump PSUView in store
175363DC PumpView in store
17438048vDC Carbonation PumpView in store
145012DCAS Faucet AssemblyView in store
193187Waste Water Container (Optional 10ltr)View in store
172148IEC Power Cord set - Schuko/EUROView in store
172152IEC Power Cord set - UKView in store
852108IEC Power Cord set - SwissView in store
171247Faucet LED Assembly - 4B (?1404)View in store

Chilled, Ambient & Hot

Part number:Description: 
171239DCAH Main Control BoardView in store
171243DCH Level Control BoardView in store
171244Faucet LED Assembly - 6BView in store
1324481/4" PF x 1/4" Stem Single Check ValveView in store
1314262-Port Drainage OutletView in store
120515Door Panel (Shell only)View in store
120521Door Panel InfillView in store
121515Side Panel - LeftView in store
123155Left Top Panel Cover PlateView in store
123156Right Top Panel Cover PlateView in store
145015Waste Drain GrillView in store
121516Side Panel - RightView in store
171244Faucet LED Assembly - 6BView in store
172144IEC Power Cord set - DanishView in store
173241Solenoid ValveView in store
173267Cold ThermostatView in store
173274Leak Detector ProbeView in store
173277Leak Detector ModuleView in store
174352FanView in store
184565Cup Dispenser Tube SetView in store
174323IEC FuseView in store
193165Waste Water Container (2 ltr)View in store
172231Compressor Relay SetView in store
166982Hot Water TankView in store
174370Hot Water Pump AssemblyView in store
17326592C Temperature SensorView in store
173255105C Safety Temperature Cut-out SensorView in store
191173S42 DCAS Control Button MembraneView in store
191175Control Button Membrane Under LinerView in store
194121Grit FilterView in store
184602Inner Front CoverView in store
123154Upper Top PanelView in store
17437724vDC PSUView in store
175363DC PumpView in store
191174DCHS Control Button MembraneView in store
193187Waste Water Container (Optional 10ltr)View in store
172148IEC Power Cord set - Schuko/EUROView in store
172152IEC Power Cord set - UKView in store
852108IEC Power Cord set - SwissView in store
171247Faucet LED Assembly - 4B (?1404)View in store

Chilled, Hot & Sparkling

Part number:Description: 
171240DCHS Main Control BoardView in store
171242DCS Level Control BoardView in store
171244Faucet LED Assembly - 6BView in store
1314262-Port Drainage OutletView in store
121515Side Panel - LeftView in store
123155Left Top Panel Cover PlateView in store
123156Right Top Panel Cover PlateView in store
145015Waste Drain GrillView in store
171249H Level Control BoardView in store
171244Faucet LED Assembly - 6BView in store
172144IEC Power Cord set - DanishView in store
173241Solenoid ValveView in store
173267Cold ThermostatView in store
174352FanView in store
184565Cup Dispenser Tube SetView in store
174323IEC FuseView in store
194121Grit FilterView in store
172231Compressor Relay SetView in store
166982Hot Water TankView in store
174370Hot Water Pump AssemblyView in store
17326592C Temperature SensorView in store
173255105C Safety Temperature Cut-out SensorView in store
191174DCHS Control Button MembraneView in store
191175Control Button Membrane Under LinerView in store
120515Door Panel (Shell only)View in store
120521Door Panel InfillView in store
173274Leak Detector ProbeView in store
193165Waste Water Container (2 ltr)View in store
173277Leak Detector ModuleView in store
1324481/4" PF x 1/4" Stem Single Check ValveView in store
121516Side Panel - RightView in store
123154Upper Top PanelView in store
17437724vDC PSUView in store
175363DC PumpView in store
17438548vDC Carbonation Pump PSUView in store
17438048vDC Carbonation PumpView in store
184602Inner Front CoverView in store
171247Faucet LED Assembly - 4B (?1404)View in store
172148IEC Power Cord set - Schuko/EUROView in store
172152IEC Power Cord set - UKView in store
852108IEC Power Cord set - SwissView in store
145013DCHS Faucet AssemblyView in store
193187Waste Water Container (Optional 10ltr)View in store

Technical Information

Chilled & Ambient Electrical Circuit Diagram

Chilled, Ambient & Sparkling Electrical Circuit Diagram

Chilled, Ambient & Hot Electrical Circuit Diagram

Chilled, Hot & Sparkling Electrical Circuit Diagram

Chilled & Ambient Water Pathway Diagram

Chilled, Ambient & Sparkling Water Pathway Diagram

Chilled, Ambient & Hot Water Pathway Diagram

Chilled, Hot & Sparkling Water Pathway Diagram

Specification

COOLING SYSTEMAll ModelsHigh efficiency compression system with capillary control. Premium quality long life hermetic compressor. Compact internal condenser – fan assisted for greater efficiency.
Environmentally friendly R600 refrigerant. 3.5 litre
insulated stainless steel chiller tank with level control
containing stainless steel cold water direct chill coil.
Thermostatically controlled chilled water temperature.
Stainless steel carbonator tank with independent level
control fitted inside coil. High capacity, low voltage
diaphragm inlet pump.
HEATING SYSTEMChilled, Ambient
& Hot
High efficiency compression system with capillary control. Premium quality long life hermetic compressor. Compact internal condenser – fan assisted for greater efficiency.
Environmentally friendly R600 refrigerant. 3.5 litre
insulated stainless steel chiller tank with level control
containing stainless steel cold water direct chill coil.
Thermostatically controlled chilled water temperature.
1.75lt stainless steel hot water tank with thermostatic
temperature control (92C max), insulated for energy conservation.
Chilled, Hot &
Sparkling
High efficiency compression system with capillary control. Premium quality long life hermetic compressor. Compact
internal condenser – fan assisted for greater efficiency.
Environmentally friendly R600 refrigerant. 3.5 litre
insulated stainless steel chiller tank with level control
containing stainless steel cold water direct chill coil.
Thermostatically controlled chilled water temperature.
Stainless steel carbonator tank with independent level
control fitted inside coil and high capacity, low voltage
diaphragm inlet pump.1.75lt stainless steel hot water tank
with thermostatic temperature control (92C max), insulated
for energy conservation.
COLD TEMPRATURE2°C to 11°C
HOT TEMPRATURE92°C Max
THROUGHPUT PER HOUR 18 litres cold < 12°C / 16 litres sparkling <12°C
DISPENSEErgonomically designed and situated light touch sensitive controls.
MAXIMUM RUNNING POWER CONSUMPTIONChilled & Ambient100 watt
Chilled, Ambient &
Sparkling
140 watt
Chilled, Ambient & Hot900 watt
Chilled, Hot & Sparkling940 watt
POWER SUPPLYIEC power socket.
WATER CONNECTION1/4 inch quick connection.
C02 CONNECTION1/4 inch quick connection.
COUNTERTOP DIMENSIONS(w x d x h) 520 x 410 x 1010mm
WEIGHTSChilled & Ambient27.0kg
Chilled, Ambient &
Sparkling
30.9kg
Chilled, Ambient & Hot27.8kg
Chilled, Hot & Sparkling31.6kg