Release date 07.10.2021

Viovandt UV Purification

Model Overview

Introduction

acuva-Introduction-01
  1. Power connection to Class 2 power supply
  2. Indicator light
  3. Water outlet
  4. Water inlet

Specifications

CertificationNSF/ANSI-55 Class “B” and NSF/ANSI 372
Dose Delivery>16 mJ/cm2
Certified Flow Rate1.0 L/min
Water Inlet Fitting¼” OD Push-to-Connect
Water Outlet Fitting¼” OD Push-to-Connect
Input Voltage11-16V DC
Power Consumption (Active)Approx. 5.0W
Power Consumption (Standby)Approx. 0.1W
Maximum Water Temperature40oC
Maximum Working Pressure100 PSI
Minimum Working Pressure12 PSI
LED Life-time1,000 hr (on demand)

Box Contents

  • 1 X Acuva Eco – UV 
  • 1 X Power adaptor 
  • 1 X DIN Rail 
  • 1 X US Power Cable 
  • 1 X EU Cable (EU ONLY) 
  • 1 X UK Cable (UK only) 
  • 1 X Manual 

Indicator Light

The indication light shows various modes of use. 

  • No Light: The device is idle, or no power is connected. 
  • Blue Light: The device is active and disinfecting water. 
  • Red Light: There is a fault in the device. 

Mounting the Unit

The Din rail should be attached securely to the surface the unit will be installed on using appropriate fixings for both the wall material and to hold the weight of the unit. 

The rail orientation should ensure the unit will be installed in one of the configurations below. 

acuva-mounting-the-unit

Mounting the Unit to rail

  • Engage the spring-loaded mechanism of the mounting clips on the device by hooking the clip onto the bottom edge of the DIN-rail and applying slight pressure upwards.
  • As the bottom portion engages, tilt the upper hook towards the DIN-rail.
  • Release the spring mechanism once the unit is mounted on the rail.
acuva-mounting-the-unit-to-rail
  1. DIN Rail
  2. Spring-loaded mechanism

Safety Information and Warnings

This section contains important information regarding the safe installation and operation of the Eco UV 1.0. 

PLEASE READ CAREFULLY. 

  • Installation or operation of the device in a manner contrary to this manual may result in property damage or personal injury. 
  • Warnings and Safety Precautions 


DANGER
 

  • Device must be connected to a Class 2 power supply (12V DC ± 5%, 0.5A output) Do not store the device in freezing conditions. 
  • Do not allow water to freeze in the device. 
  • Do not use the device if damaged or dropped. Do not submerge the device under water. 
  • Do not connect to AC power without an AC to DC power adapter; this device uses DC via Class 2 power supply only. 
  • This product is not ignition protected. Do not install in an engine compartment or other areas where explosive vapours may be present.