Model Overview
Introduction
A range of compact water dispensers, available as a Reservoir (gravity fed) system and a Direct Chill system:
• Reservoir Chilled & Ambient
• Reservoir Chilled & Hot
• Direct Chill Cold & Ambient
• Direct Chill Cold & Hot
The b2 model is available as countertop and floor standing in three colours.
All Models
All models are self-contained machines with robust steel chassis and attractively injection moulded plastic front and top panels. For floorstanding models there is sufficient space internally for most filters. For countertop models any filters would need to be fitted externally. An IEC Power Lead is supplied for connection to the IEC socket found on the rear of all models (An additional Schuko type is supplied for the
European market).
Chilled
Water is fed into the insulated cold tank under mains pressure. We strongly recommend a Pressure Reducing Valve is fitted to all supplies to regulate the
pressure to 3.5 bar/355 KPat. The cold tank is chilled via the evaporation coil of the capillary controlled
refrigeration compression system. The cold temperature is thermostatically controlled via the adjustment screw on the cold thermostat. This is factory set and is not necessary to adjust in most cases (see Controls).
Ambient
Water bypasses the cold tank for the ambient dispense option in the case of direct chill models, for reservoir models water is fed down through the baffle
plate located inside the cold tank.
Hot
Hot water is provided by a hot water tank with an external heating element. Water is supplied directly into the tank under gravity fed pressure, and when full hot water is dispensed by displacement. The water flow is controlled by either a solenoid valve (direct chill models) or by a tap (reservoir models).
Direct Chill
Borg & Overström Direct Chill utilises innovative technology to chill water instantly. We recommend this system for more demanding environments because of its optimum dispense performance and unrivalled hygienic qualities. Superior to the gravity
fed Reservoir system, Direct Chill technology chills water on demand for the ultimate drinking experience.
Controls
Cold Thermostat
Chilled
On/Off Switch: at rear of machine, switches cooling operation on/off.
Cold Thermostat: At rear of machine.
NOTE: on a Direct Chill model this is located inside.
Cold Tap: Push tap lever down.
Reservoir Models – Cold & Ambient only:
Green LED: Cooling operation is switched on.
Yellow LED: Colour shows compresor is in operation.
Ambient
Ambient Tap: Push tap lever down.
Hot
On/Off Switch: The hot water heating mode
is controlled by a switch on the back of the unit, next to the cooling mode switch. This switch is labelled “Hot”.
Hot Thermostat: regulated by a pre-set, nonadjustable sensor on the tank.
Hot Tap: Lift red safety tab and push down lever.
Red LED (on hot water icon): Colours to show heating mode is enabled.
Reservoir Models – Cold & Hot only:
Green LED: Cooling operation is switched on.
Yellow LED: Hot operation is switched on.
Red LED: Heater element active according to thermostatic demand.
10A Fuse: On rear of machine, integral with
IEC socket.
Components
Major Components & Water Connection - Reservoir variant
Major Components & Water Connection - Direct Chill variant
Operation
Water Connection & Operation
On reservoir models remove the Carbon bag from the cold tank. Connect and turn on the water supply. Then connect the power supply.
Dispense from all options (to confirm water supply).
Turn on the cold switch (located at the rear on the unit) to begin the chilling process. Turn on the hot switch (also located at the rear on the unit) to activate the heating element.
The relevant indicator lights will be lit.
Flush through 10 litres of water before use.
Chilled & Ambient:
When the Green LED is on the cooling circuit is activated. When the Yellow LED is on the
compressor is operating.
Chilled & Hot:
When the Green LED is on the cooling circuit is activated. When the Yellow LED is on heating circuit is activated. When the Red LED is on the heating element is activated.
Allow up to 1 hour for the water to reach its minimum
temperature.
The temperature of the chilledwater can be set from 4c to 10c. When the chilling LED is off the set temperature has been reached. This can take up to one hour.
Functions & Controls
General Safety
Maintenance
NOTE: All maintenance opertaions must be carried out with the dispenser switched off.
Isolation & Removal
Please make sure the machine is completely disconnected from the electrical supply before carrying out any maintenance work.
Turn off the water supply.
To drain cold and ambient units, simply push each tap lever untill no water dispense. For cold and hot dispensers push the cold dispense until no water dispenses and then remove the drain bung to empty the hot water tank.
Caution: hot water may spill from the hot tank during this operation.
Sanitisation Guide
NOTE: Before beginning the sanitation process please ensure that water is turned off at the mains and refer to the MSDS document for further information. Use bioguard hand gel and ensure gloves are worn.
For reservoir variants always ensure that the hot water outlet is plugged before beginning this procedure (use gloves). Never push the hot water button during the sanitisation procedure.
Remove the top panel by undoing 2x screws at the rear
of the dispenser.
Remove the polystyrene lid. Gently lift the plastic lid from the tank, taking care not to disconnect the plumbing.
Dispense chilled water until the baffle plate is accessible.
Insert the Hot tank sanitisation plug into the centre of the hot tank, press down firmly. Refit the plastic lid to the tank.
Follow steps 1-12below.
Once the sanitisation procedure is complete repeat step 3 and reverse step 4 above, then remove the Hot tank sanitisation plug and replace the plastic lid firmly on the tank, then replace the polystyrene lid and top panel. Ensuring the screws are done up before leaving.
Briefly press chilled/ambient dispense buttons to release internal water pressure from the machine.
Remove the existing filter.
Add 25 ml of Sterizen® 30 Internal Water Cooler Sanitiser fluid to a clean and empty service filter cartridge.
Connect to machine.
Turn on incoming water, allow service cartridge/doser to fill.
Dispense water using the chilled button until the water
appears pink. Briefly press the ambient button too.
Leave the solution inside machine for sanitisation
(minimum 5 minutes) while thoroughly cleaning the
machine externally, pay particular attention to the dispense faucet and buttons.
Remember to include the drip tray. If a Waste Overflow System is fitted, empty this and flush through with a small amount of sanitisation fluid if needed.
When the external cleaning (minimum 5 minutes) is completed, flush the machine using the chilled button with clean water until the dispense water runs clear. Repeat briefly with the ambient button.
Turn off water and remove the service filter. Retain service filter for reuse.
Fit new filter. Turn on incoming water supply.
Pre-flush the new filter to waste using the ambient button until the water appears clear and is free of air. Flush through a small amount of water to check all functions.
Advanced Troubleshooting
Fault Diagnosis: No Water Dispenses
Problem/Report | Possible Cause | Suggested Action |
---|---|---|
From Ambient Tap | Water Supply turned off (and tank empty) | Check all that taps/valves/ filters on the incoming supply are fitted and are turned on. |
“Waterblock” tripped off (and tank empty). | Reset “Waterblock” (and check for any leaks). | |
“Leak detector” (if fitted) tripped off (and tank empty). | Disconnect the power and water supply, reset the machine (check for leaks). | |
Tap not working (and tank full). | Dismantle and check the tap,completely replacing the tap or just the washer as necessary | |
Reservoir Float Valve jammed (and tank empty). | Replace/adjust postion /repair as needed | |
Blocked tank outlets/pipes. | Check and unblock or replace as needed. | |
From Cold Tap | Firstly all as for Ambient Tap | Carry out checks and actions as for Ambient Tap |
Chiller tank frozen – Thermostat set too low. | Thaw out the machine and increase cold water temperature. | |
Chiller tank Frozen - Thermostat not working. | Thaw out the machine and check thermostat. Replace Cold Water thermostat as needed. | |
From Hot Tap | Firstly all as for Ambient Tap. | Carry out checks and actions as for Ambient Tap. |
Airlock in dispense pipe work. | Unblock/replace hot water pipe and hot vent pipe. (Check water level showing in hot vent pipe). | |
Tank filled with limescale. | Replace tank. |
Fault Diagnosis: Water Dispenses but not Correct Temperature
Problem/Report | Possible Cause | Suggested Action |
---|---|---|
Ambient Water too Warm | Low usage and/or heat from compressor influencing stored water. | Check tank insulation and/or advise customer. |
High usage and/or water supply pipe in warm ducting. | Advise customer. | |
Cold Water not Cold | Cooling switched off. | Check switch positions as necessary. |
Compressor runs and switching off (cool/warm to touch) - Thermostat set too high. | Decrease cold thermostat set point. | |
Thermostat not working. | Check/replace thermostat. | |
Compressor runs but not switching off (hot to touch). | Please contact technical support. | |
Refrigeration problem | Please contact technical support. | |
Compressor not running at all. | Please contact technical support. | |
No electricity power supply. | Check the Power cord is connected and live, and the machine is switched on. | |
Compressor only hums slightly/ briefly. | Check and replace relays. | |
Relays loose. | Check and refit relays. | |
Compressor not working. | Please contact technical support. | |
Cold tank Baffle Plate not connected. | Refit Baffle Plate. | |
Hot Water not Hot | Hot water mode switched off | Switch on hot water mode (status LED should show). |
Heating operation tripped off. | Reset overheat button on hot tank. | |
Break in supply wiring to control circuit. | Locate break and repair. | |
Hot water demand too high. | Advise user/s. | |
Main reheat element not working (Red LED on all the time). | Check supply voltage and current to hot thermostat and replace accordingly | |
Hot tank heavily scaled (signs of scale in top of tank, loud boiling noises etc). | Carry out thorough descale or replace hot tank. | |
Break in supply wiring to main element. | Locate break and repair. |
Fault Diagnosis: Water Leaks
Problem/Report | Possible Cause | Suggested Action |
---|---|---|
Water lying on top edge of lower door panel and/or bottom of the machine. | Overflowing Drip Tray waste container. | Empty Waste Container and check drainpipe is not blocked. |
Water lying in bottom of machine | Leak in supply inlet pipe work and/ or filter. | Locate and repair accordingly. |
Leak from machine water pipes and/or fittings. | Locate and repair accordingly. | |
Overflowing cold tank. | Reservoir Variant: float valve not connected or malfunctioning - replace if necessary. Direct Chill Variant: float valve or internal cold tank water fittings not connected or malfunctioning - replace if necessary. | |
Water pressure too high. | Check pressure and fit pressure reducing valve if needed. | |
Jammed float valve. | Check and repair float valve. | |
Split Float Valve washer. | Replace washer. | |
Overflowing cold tank (Hot Tank exclusively sealed). | Replace hot tank. | |
Hot Tank thermistor probe not working. | Check and replace probe (Conversion Kit recommended). | |
Control Board not working. | Check and replace main control board (Conversion Kit recommended). | |
Condensation from tank or cold water pipe. | Check insulation and repair/replace accordingly. |
Fault Diagnosis: Miscellaneous
Problem/Report | Possible Cause | Suggested Action |
---|---|---|
No LED control lights | No eletricity to Machine. | Check power supply and reconnect as necessary (Also check out other symptoms as described separately). |
Control PCB not working (Machine working normally otherwise). | Check/replace PCB. | |
Machine Shakes on Start-up | Compressor Starting. | No action needed. This is quite normal. |
Level Surface. | ||
Uneven Surface. | Level up machine using adjustable feet. | |
Missing Fixings. | Replace missing fixings. | |
Tripping out Electricity Supply | Machine in high humidity environment. | Discuss possible repositioning with customer. |
Electrical circuitry faults. | Test, identify and address accordingly. See Electrical Diagrams. | |
Please contact technical support. |
Exploded Diagrams
Chilled & Ambient – Reservoir
Part number: | Description: | |
---|---|---|
123818 | b2 NG Top Cover Panel Black | View in store |
135729 | b2/b3 Floorstanding Reservoir Insulation Top | View in store |
133410 | Clip on Tank lid Assembly | View in store |
131647 | 1/4" Push Fit Elbow | View in store |
132457 | Reservoir Float Valve (Lid type) - Assembly | View in store |
852108 | IEC Power Cordset - Swiss | View in store |
172152 | IEC Power Cordset - UK | View in store |
172148 | IEC Power Cordset - Shucko/EURO | View in store |
172144 | IEC Power Cordset - Danish | View in store |
135727 | b2/b3 Floorstanding Reservoir Insulation Sleeve | View in store |
133419 | Reservoir Baffle Plate | View in store |
462013 | 1/4" White Tubing per mtr | View in store |
131425 | Insert for Cold Tank | View in store |
134583 | Cold Water Pipe | View in store |
174231 | Electric Rocker Switch | View in store |
173251 | b2/b3 Cold Thermostat | View in store |
131642 | 1/4" PF Inlet Elbow Bulkhead Connector | View in store |
131641 | 1/4" PF Inlet Straight Bulkhead Connector | View in store |
172163 | IEC Fused Socket | View in store |
120909 | b2 NG Front Panel - Black | View in store |
120908 | b2 NG Front Panel - White | View in store |
120907 | b2 NG Front Panel - Silver | View in store |
142121 | b2 NG Cold Tap | View in store |
121956 | b2/b3 Floorstanding Right Side Panel | View in store |
134582 | Ambient Water Pipe | View in store |
142122 | b2 NG Ambient Tap | View in store |
171201 | b2 CA Circuit Board | View in store |
126821 | b2 NG Tap Cover Panel - Black | View in store |
191145 | b2 NG Reservoir Chilled & Ambient Control Panel Label | View in store |
184622 | Magnetic door catch including screw | View in store |
125823 | b2 NG Drip Tray Set - Black | View in store |
121859 | Side Handle | View in store |
184601 | b2/b3 Floorstanding Filter Bracket | View in store |
120972 | b2 NG Door Panel - Silver | View in store |
120973 | b2 NG Door Panel - White | View in store |
120974 | b2 NG Door Panel - Black | View in store |
121955 | b2/b3 Floorstanding Left Side Panel | View in store |
124952 | b3 Floorstanding Base Panel | View in store |
184531 | b2/b3 Floorstanding Adjustable Foot | View in store |
Chilled & Hot - Reservoir
Part number: | Description: | |
---|---|---|
123818 | b2 NG Top Cover Panel Black | View in store |
135729 | b2/b3 Floorstanding Reservoir Insulation Top | View in store |
133410 | Clip on Tank lid Assembly | View in store |
131647 | 1/4" Push Fit Elbow | View in store |
132457 | Reservoir Float Valve (Lid type) - Assembly | View in store |
135727 | b2/b3 Floorstanding Reservoir Insulation Sleeve | View in store |
133419 | Reservoir Baffle Plate | View in store |
131425 | Insert for Cold Tank | View in store |
462013 | 1/4" White Tubing per mtr | View in store |
134583 | Cold Water Pipe | View in store |
174231 | Electric Rocker Switch | View in store |
172163 | IEC Fused Socket | View in store |
173251 | b2/b3 Cold Thermostat | View in store |
121859 | Side Handle | View in store |
121955 | b2/b3 Floorstanding Left Side Panel | View in store |
142123 | b2 NG Hot Tap | View in store |
142121 | b2 NG Cold Tap | View in store |
184601 | b2/b3 Floorstanding Filter Bracket | View in store |
124952 | b3 Floorstanding Base Panel | View in store |
184531 | b2/b3 Floorstanding Adjustable Foot | View in store |
131641 | 1/4" PF Inlet Straight Bulkhead Connector | View in store |
131642 | 1/4" PF Inlet Elbow Bulkhead Connector | View in store |
121956 | b2/b3 Floorstanding Right Side Panel | View in store |
120907 | b2 NG Front Panel - Silver | View in store |
120908 | b2 NG Front Panel - White | View in store |
120909 | b2 NG Front Panel - Black | View in store |
120974 | b2 NG Door Panel - Black | View in store |
120973 | b2 NG Door Panel - White | View in store |
120972 | b2 NG Door Panel - Silver | View in store |
125823 | b2 NG Drip Tray Set - Black | View in store |
171202 | b2 CH Circuit Board | View in store |
126821 | b2 NG Tap Cover Panel - Black | View in store |
131661 | 1/4" Equal Elbow Stem only | View in store |
154521 | Hot Vent Pipe - 300mm | View in store |
154524 | Hot Tank Feed Pipe | View in store |
154523 | Hot Water Pipe/DC Tank Pipe | View in store |
173265 | 90C/105C Hot Tank Sensor Set | View in store |
166880 | b2/b3 Hot Tank (New) c/w HB & 90/105 TC Set | View in store |
131423 | b2 Countertop Drain Bung | View in store |
172144 | IEC Power Cordset - Danish | View in store |
172148 | IEC Power Cordset - Shucko/EURO | View in store |
172152 | IEC Power Cordset - UK | View in store |
852108 | IEC Power Cordset - Swiss | View in store |
191146 | b2 NG Reservoir Chilled & Hot Control Panel Label | View in store |
184622 | Magnetic door catch including screw | View in store |
Chilled & Ambient - Direct Chill
Part number: | Description: | |
---|---|---|
123818 | B2 NG Top Cover Panel Black | View in store |
133416 | DC Cold Tank Lid | View in store |
135721 | DC Cold Tank Lid insulation | View in store |
131642 | 1/4" PF Inlet Elbow Bulkhead Connector | View in store |
462013 | 1/4" White Tubing per mtr | View in store |
133418 | B2 Direct Chill Header Tank Lid | View in store |
852108 | IEC Power Cordset - Swiss | View in store |
172152 | IEC Power Cordset - UK | View in store |
172148 | IEC Power Cordset - Shucko/EURO | View in store |
172144 | IEC Power Cordset - Danish | View in store |
174310 | Direct chill Pump | View in store |
133415 | DC Cold Tank Inner Lid | View in store |
132456 | Reservoir Float Valve (Side Type) - Assembly | View in store |
131422 | 1/4" Inlet Connector Back Nut | View in store |
134601 | DC Coil for Twin Tank Models | View in store |
131647 | 1/4" Push Fit Elbow | View in store |
133414 | B2 Direct Chill Header Tank | View in store |
462013 | 1/4" White Tubing per mtr | View in store |
174231 | Electric Rocker Switch | View in store |
172163 | IEC Fused Socket | View in store |
462013 | 1/4" White Tubing per mtr | View in store |
131643 | 1/4" PF Stem Elbow | View in store |
462013 | 1/4" White Tubing per mtr | View in store |
131644 | 1/4" Push-Fit 4 way Joint | View in store |
131642 | 1/4" PF Inlet Elbow Bulkhead Connector | View in store |
131641 | 1/4" PF Inlet Straight Bulkhead Connector | View in store |
120909 | B2 NG Front Panel - Black | View in store |
120908 | B2 NG Front Panel - White | View in store |
120907 | B2 NG Front Panel - Silver | View in store |
194121 | Grit Filter | View in store |
173251 | B2/B3 Cold Thermostat | View in store |
131424 | DC Tank Pipe Connector | View in store |
154523 | Hot Water Pipe/DC Tank Pipe | View in store |
134581 | DC Tank Pipe | View in store |
173249 | HP1/4PFx1/2STS230 Solenoid Valve | View in store |
121956 | B2/B3 Floorstanding Right Side Panel | View in store |
171204 | B2 CA DC Main Control Board | View in store |
126822 | B2 NG DC Tap Cover Panel - Black | View in store |
191147 | B2 NG Direct Chill Chilled & Ambient Control Panel Label | View in store |
151544 | B2/B3 Floorstanding Drain Bung | View in store |
184415 | Grommet for B2 NG DC | View in store |
121859 | Side Handle | View in store |
121955 | B2/B3 Floorstanding Left Side Panel | View in store |
184625 | Solenoid Valve Bracket for b2 | View in store |
133512 | B2 DC Faucet (Light Grey w/o vent) | View in store |
184622 | Magnetic door catch including screw | View in store |
184622 | Magnetic door catch including screw | View in store |
120972 | B2 NG Door Panel - Silver | View in store |
120973 | B2 NG Door Panel - White | View in store |
120974 | B2 NG Door Panel - Black | View in store |
184601 | B2/B3 Floorstanding Filter Bracket | View in store |
124952 | B3 Floorstanding Base Panel | View in store |
184531 | B2/B3 Floorstanding Adjustable Foot | View in store |
Chilled & Hot - Direct Chill
Part number: | Description: | |
---|---|---|
123818 | b2 NG Top Cover Panel Black | View in store |
133416 | DC Cold Tank Lid | View in store |
135721 | DC Cold Tank Lid insulation | View in store |
131642 | 1/4" PF Inlet Elbow Bulkhead Connector | View in store |
462013 | 1/4" White Tubing per mtr | View in store |
852108 | IEC Power Cordset - Swiss | View in store |
172152 | IEC Power Cordset - UK | View in store |
172148 | IEC Power Cordset - Shucko/EURO | View in store |
172144 | IEC Power Cordset - Danish | View in store |
174310 | Direct chill Pump | View in store |
133415 | DC Cold Tank Inner Lid | View in store |
131422 | 1/4" Inlet Connector Back Nut | View in store |
134601 | DC Coil for Twin Tank Models | View in store |
133418 | b2 Direct Chill Header Tank Lid | View in store |
131646 | Air Vent Elbow for Clip-on Tank Lid | View in store |
132456 | Reservoir Float Valve (Side Type) - Assembly | View in store |
154551 | L-shape Silicon Tube | View in store |
174231 | Electric Rocker Switch | View in store |
154521 | Hot Vent Pipe - 300mm | View in store |
131649 | 1/4" Push Fit Tee | View in store |
133414 | b2 Direct Chill Header Tank | View in store |
131642 | 1/4" PF Inlet Elbow Bulkhead Connector | View in store |
131641 | 1/4" PF Inlet Straight Bulkhead Connector | View in store |
174231 | Electric Rocker Switch | View in store |
131643 | 1/4" PF Stem Elbow | View in store |
173251 | b2/b3 Cold Thermostat | View in store |
120909 | b2 NG Front Panel - Black | View in store |
120908 | b2 NG Front Panel - White | View in store |
120907 | b2 NG Front Panel - Silver | View in store |
172163 | IEC Fused Socket | View in store |
131643 | 1/4" PF Stem Elbow | View in store |
194121 | Grit Filter | View in store |
462013 | 1/4" White Tubing per mtr | View in store |
121956 | b2/b3 Floorstanding Right Side Panel | View in store |
173246 | LP1/4PFx1/2STS230 Solenoid Valve | View in store |
131424 | DC Tank Pipe Connector | View in store |
171205 | b2 CH DC Main Control Board | View in store |
126822 | b2 NG DC Tap Cover Panel - Black | View in store |
191148 | b2 NG Direct Chill Chilled & Hot Control Panel Label | View in store |
154523 | Hot Water Pipe/DC Tank Pipe | View in store |
134581 | DC Tank Pipe | View in store |
121859 | Side Handle | View in store |
166880 | b2/b3 Hot Tank (New) c/w HB & 90/105 TC Set | View in store |
173249 | HP1/4PFx1/2STS230 Solenoid Valve | View in store |
184625 | Solenoid Valve Bracket for b2 | View in store |
133512 | b2 DC Faucet (Light Grey w/o vent) | View in store |
125823 | b2 NG Drip Tray Set - Black | View in store |
154536 | Hot Tank Silicon Feed Pipe | View in store |
184622 | Magnetic door catch including screw | View in store |
173265 | 90C/105C Hot Tank Sensor Set | View in store |
121955 | b2/b3 Floorstanding Left Side Panel | View in store |
131423 | b2 Countertop Drain Bung | View in store |
120972 | b2 NG Door Panel - Silver | View in store |
120973 | b2 NG Door Panel - White | View in store |
120974 | b2 NG Door Panel - Black | View in store |
184601 | b2/b3 Floorstanding Filter Bracket | View in store |
124952 | b3 Floorstanding Base Panel | View in store |
184531 | b2/b3 Floorstanding Adjustable Foot | View in store |
Technical Information
Chilled & Ambient Electrical Circuit Diagram - Reservoir Variant
Chilled & Hot Electrical Circuit Diagram - Reservoir Variant
Chilled & Ambient Electrical Circuit Diagram - Direct Chill Variant
Chilled & Hot Electrical Circuit Diagram - Direct Chill Variant
Chilled & Ambient Water Pathway Diagram - Reservoir Variant
Chilled & Hot Water Pathway Diagram - Reservoir Variant
Chilled & Ambient Water Pathway Diagram - Direct Chill Variant
Chilled & Hot Water Pathway Diagram - Direct Chill Variant
Specification
COOLING SYSTEM | All Models | High efficiency compression system with capillary control. Premium quality long life hermetic compressor. External condenser. Environmentally friendly R134A refrigerant. |
---|---|---|
Reservoir - Chilled & Ambient | High volume 3.5 litre stainless steel gravity fed cold tank for optimum water capacity on demand. Insulated tank for energy conservation. Large volume output. Thermostatically controlled chilled water temperature (range down to 2°C minimum). | |
Direct Chill - Chilled & Ambient | Sealed Direct Chill Ice bank tank for optimum water capacity on demand and hygiene. Low sanitisation and maintenance. Insulated tank for energy conservation. Large volume output via electronic solenoid valves. Thermostatically controlled chilled water temperature (range down to 2°C minimum). | |
HEATING SYSTEM | Reservoir - Chilled & Hot | High volume 3.5 litre stainless steel gravity fed cold tank for optimum water capacity on demand and hygiene with low sanitisation and maintenance requirement. Thermostatically controlled chilled water temperature (range down to 2°C minimum). 1.7lt stainless steel hot water tank with thermostatic temperature control (90°C max). Insulated tanks for energy conservation. |
Direct Chill - Chilled & Hot | Sealed Direct Chill Ice bank tank for optimum water capacity on demand and hygiene, with low sanitisation and maintenance requirement. Output via electronic solenoid valves. Thermostatically controlled chilled water temperature (range down to 2°C minimum). 1.7lt stainless steel hot water tank with thermostatic temperature control (90°C max). Insulated tanks for energy conservation. | |
COLD TEMPRATURE | 2°C to 11°C | |
HOT TEMPRATURE | 90°C Max | |
THROUGHPUT PER HOUR | 22 litres cold 85°C | |
DISPENSE | Reservoir variants have a manual tap system, and Direct Chill Variants have a light touch sensitive control panel. | |
MAXIMUM RUNNING POWER CONSUMPTION | Chilled & Ambient | 100 watt |
Chilled & Hot | 535 watt | |
POWER SUPPLY | IEC power socket. | |
WATER CONNECTION | 1/4 inch quick connection. | |
COUNTERTOP DIMENSIONS | (w x d x h) 325 x 365 x 475mm | |
FLOORSTANDING DIMENSIONS | (w x d x h) 325 x 365 x 1060mm | |
COUNTERTOP WEIGHTS | Reservoir Chilled & Ambient | 13.4kg |
Reservoir Chilled & Hot | 14.0kg | |
Direct Chill Chilled & Ambient | 14.7kg | |
FLOORSTANDING WEIGHTS | Reservoir Chilled & Ambient | 21.2kg |
Reservoir Chilled & Hot | 21.8kg | |
Direct Chill Chilled & Ambient | 21.5kg | |
Direct Chill Chilled & Hot | 22.5kg |