- Model Overview
- Installation
- Operation
- Maintenance
- Advanced Troubleshooting
- Exploded Diagrams
- Technical Information
- Chilled & Ambient Electrical Circuit Diagram
- Chilled, Ambient & Sparkling Electrical Circuit Diagram
- Chilled, Ambient & Hot Electrical Circuit Diagram
- Chilled, Hot & Sparkling Electrical Circuit Diagram
- Chilled & Ambient Water Pathway Diagram
- Chilled, Ambient & Sparkling Water Pathway Diagram
- Chilled, Ambient & Hot Water Pathway Diagram
- Chilled, Hot & Sparkling Water Pathway Diagram
- Specification
Release date 13.05.2018
B5 Install & Operation Manual
Model Overview
Introduction
A range of compact water dispensers, available in four different operational types:
• Chilled & Ambient
• Chilled, Ambient & Sparkling
• Chilled, Ambient & Hot
• Chilled, Hot & Sparkling
All Models
All models are self-contained machineswith robust steel framed cabinets and attractively injection moulded plastic front, side and top panels. There is
sufficient space internally for most filters to be fitted behind the door panel. An IEC Power Lead is supplied for connection to the IEC socket found on
the rear of all models (An additional
Schuko type is supplied for the European
market).
The level control system also incorporates a leak detection device within the cabinet which isolates
the water to the unit in the event of detecting a water leak.
Chilled
The cold temperature is thermostatically controlled via the adjustment screw on the back of the machine. This is factory set and is not necessary to adjust in most cases (see Controls).
Ambient
Water bypasses the cold tank for the ambient dispense option.
Sparkling
Water is chilled as it passes through the coil immediately before dispense or being pumped under pressure into the carbonator which it fitted inside the
same coil. The carbonator is also level controlled and allows the sparkling effect to occur through saturation with CO2.
Hot
The hot water is provided by hot water tank with an integrated heater element. The water is supplied directly into the tank under the pressure as connected
into the back of the unit. The water fills the tank and hot water is dispensed. The water flow is controlled by a solenoid.
Controls
Cold Thermostat
Chilled
On/Off Switch: at upper rear of machine, switches cooling operation on/off.
Cold Thermostat: at rear of machine.
Cold Button: press to dispense cold water.
Green LED (Top): Colours to show cooling operation is switched on.
Green LED (Bottom): Colours to show when compressor is operating/water is above set point.
10A Fuse: On rear of machine, integral with IEC socket.
Ambient
Ambient Button: Press to dispense ambient water.
Sparkling
Soda: Switches sparkling operation on/off.
Sparkling Button: Press to dispense sparkling water
Yellow LED (bottom RH): Colours to show the sparkling operation is switched on.
Hot
On/Off Switch: The hot water heating mode is controlled by a switch on the back of the unit, next to the cooling mode switch. This switch is labelled “Hot”.
Hot Thermostat: regulated by a pre-set, nonadjustable sensor on the tank.
Hot Button: press to dispense hot water.
Lock Button: toggles on and off the dispense of hot water.
Red LED (on hot water icon): Colours to show heating mode is enabled.
Red LED (marked heating): Colours to show heating element is active according to thermostatic demand.
Storage Cabinet
All models are fitted with a lower storage area.
The door panel is hinged and fastened with magnetic catches. There is a removable cover protecting the machine parts.
Every DC15 is supplied with a level sensor kit, comprising:
• Water container
• Level sensor module
Installation
Major Components
Water and CO2 Connection
CO2 Bottle Installation (Sparkling Versions Only
IMPORTANT! ALWAYS ENSURE SECURITY CLIPS ARE USED ON ALL WATER AND CO2 CONNECTIONS.
Attach the regulator to the disposable CO2 bottle, ensuring the regulator is closed.
Connect the assembled CO2 bottle and regulator to the machine using 1/4 inch pipe.
After completing the water installation, turn on the soda power switch and the pump will run. Do not open the regulator valve until the carbonated switch has been turned on.
We recommend between 3.5 – 5 bar. Do not exceed 5 bar pressure.
Flush through approximately 10 litres of water. Check and adjust the CO2 pressure accordingly.
It will be necessary to leave the machine for up to 1 hour for sparkling water to develop, by absorbing the CO2.
Level Sensor Assembly
Check all parts are present.
Locate and connect the drainage tubing into the top of the level sensor connector.
The LED lighting at the base of the faucet will flash slowly for 1 minute. This is also repeated every time a
dispense button is pressed.
Empty the waste container to cancel.
A WARNING TONE WILL SOUND WHEN THE WATER RISES. UPON EMPTYING THE CONTAINER THE WARNING TONE WILL STOP.
Operation
Water Connection & Operation
Connect and turn on the water supply.
Plug in the power supply, cold, hot & sparkling tanks will automatically fill.
Activate the carbonation & hot power switch (if present).
Activate cold power switch.
Flush through 10 litres of water before use.
When the cold water switch is turned on, the cold water and chilling LED will be on.
The temperature of cold water can be set from 4c to 10c.
When the chilling LED is off the set temperature has been reached. This can take up to one hour.
When the heating LED is off the pre-set temperature has been reached. This can take up to 30mins.
Functions & Controls
General Safety
Maintenance
Isolation & Removal
Please make sure the machine is completely disconnected from electricity before carrying out any maintenance work.
Turn off the water supply.
To drain the Direct Chill tank, remove the caps on the back of the machine. We recommend it is refitted immediately upon draining being completed.
Sanitisation Guide
NOTE: Before beginning the sanitation process please ensure that water is turned off at the mains and refer to the MSDS document for further information. Use bioguard hand gel and ensure gloves are worn.
Briefly press cold/ambient dispense button to release
internal water pressure from the machine.
Remove the existing filter.
Add 25 ml of Sterizen® 30 Internal Water Cooler Sanitiser fluid to a clean and empty service filter cartridge.
Connect to machine.
Turn on incoming water, allow service cartridge/doser to fill.
Dispense water using the cold button until the water appears pink. Briefly press the ambient button too. Repeat with sparkling button if present.
Leave the solution inside machine for sanitisation to take effect (minimum 5 minutes) while thoroughly cleaning the machine externally, pay particular attention to the dispense faucet and button controls.
Remember to include the drip tray. Empty the Waste Overflow System and flush through with a small amount of sanitisation fluid if needed.
When the external cleaning (minimum 5 minutes) is
completed, flush the machine using the cold button with
clean water until the dispense water runs clear. Repeat
briefly with the ambient button (and sparkling button if
present).
Turn off water and remove the service filter. Retain service filter for reuse.
Fit new filter. Turn on incoming water supply.
Pre-flush the new filter to waste using the ambient button (and sparkling button if present) until the water appears clear and is free of air. Flush through a small amount of water to check all functions.
Leak Detection
NOTE: This machine is equipped with a leakage detection device. When leaking is detected, the dispense operation will be cut off automatically. This is indicated by a blue LED flashing at the base of the tap.
To reset:
Unplug the machine and remove the protective cover.
Locate the source of leakage and rectify.
Locate the detection probe which can be found in the bottom at the rear of the machine. Dry the probes and internal area with a dry cloth.
Locate the Leak Detector valve.
Reset the red lever (push it in).
Reconnect the power to machine and test operation.
Emptying the Carbonation Tank
Switch off the Carbonation System switch on the back of the unit.
Press and hold the Sparkling water dispense button until all water is expelled.
The tank is empty of sparking water when only CO2 is being released.
Ensure to release the Sparkling water button and take care to avoid releasing excess amounts of CO2 gas.
Advanced Troubleshooting
Fault Diagnosis: No Water Dispenses
Problem/Report | Possible Cause | Suggested Action |
---|---|---|
From Ambient Valve | Water Supply turned off. | Check all taps/valves/ filters on incoming supply are fitted and are turned on. |
No Electricity/Power Supply. | Check power cord is connected and live and machine is switched on. | |
“Waterblock” tripped off (and tank empty). | Reset “Waterblock” (refer to manufacturer’s instructions and check for any leaks). | |
Check valve action. Carefully dismantle valve and clean out/ part replace/complete replace as needed. | ||
Solenoid Valve not working. | Valve clicking but no water - Check if hole in centre of washer is clear. | |
Valve not clicking - Check for voltage output from control PCB when operated (Caution-High Voltage). If not present, check wiring for continuity and/or replace PCB. If present, check coil/PCB and replace solenoid coil/whole valve coil/whole valve assembly complete/PCB as needed. | ||
“Level Sensor” Waste Water Container full (Blue LED will flash slowly when the button is pressed. This flashing cycle will repeat for 60 secs following the button being pressed). | Empty the container. (The unit will automatically reset to normal operation.) | |
Leak detector has disabled dispense operation. | Check for internal leakage, ensure probes are dry and reset. | |
From Cold Valve | Firstly all as for Ambient Tap. | Carry out checks and actions as for ambient tap. |
Chiller tank frozen – Thermostat not working correctly. | Thaw out and check thermostat. Replace Cold Water thermostat as needed. | |
Chiller tank Frozen - Tank pump not working. | Thaw out and check tank pump. Replace pump and or check electricity supply to pump present. |
Problem/Report | Possible Cause | Suggested Action |
---|---|---|
From All Valves | Button not being pressed enough. | Press button firmly. |
PCB control not working. | Check/replace as necessary. | |
From Sparkling Valve | Firstly as for ambient and cold valve. | Carry out the checks and actions as for cold and ambient. |
Low or no CO2. | Check and replace cylinder as necessary. | |
Pump not operating. | Check carbonator level control system. | |
Check probes connected/Leads attached. Check power supply to pump. | ||
Carbonator Tank over pressurised with CO2. | 1. Switch the Sparkling System off. 2. Shut off CO2 supply. 3. Press the Sparkling Water button to release CO2 from carbonator. 4. Switch the Sparkling system on. 5. Check pump operation is running normally. 6. Wait for the pump to stop running. 7. Re-open CO2 supply. | |
Pump Feed Solenoid Valve. | Check function/condition and repair/replace accordingly. | |
Carbonation System switched off. | Switch on (Switch on back of the machine). | |
From Hot Valve | Hot water lock button not being pressed. | Press hot water lock button prior to hot water button. |
If during first installation: Ensure that the hot tank has filled. This fills automatically upon first installation – allow 2-3 mins. | Check and follow installation instructions. | |
If following normal usage: Follow the same guidance as for ‘Ambient’ valve. | Carry out checks. | |
Hot Tank Level Probes disconnected. | Check and rectify, as necessary. | |
Hot Tank Level Probes have limescale build-up/damage. | Check and clean/replace, as necessary. | |
Hot Tank Level Control Failed. | Replace Hot Tank Level Control Board. | |
Hot Tank has excessive limescale build-up. | Check & Replace Hot Tank as necessary. | |
Hot Safety dispense function not working. | Check & replace Main Control Board as necessary. | |
Hot Tank Solenoid (fill solenoid) failed. | Check & Replace as necessary. | |
Hot Water Dispense Pump failed. | Check & Replace as necessary. | |
Hot Water dispense pipe blocked. | Check & Replace as necessary. |
Fault Diagnosis: Water Dispenses but not Correct Temperature
Problem/Report | Possible Cause | Suggested Action |
---|---|---|
Ambient Water too Warm | Low usage and/or fed from water supply pipe in warm ducting. | Advise user replacing external causes and solutions. |
Cold Water not Cold | Cooling switched off. | Check switch positions. |
Compressor runs and switching off (cool/warm to touch) - Thermostat set too high. | Decrease Cold Thermostat set point. | |
Thermostat not working. | Check and replace as necessary. | |
Compressor runs but not switching off. | Please contact technical support. | |
Refrigeration problem. | Please contact technical support. | |
Compressor not running at all. | Check and trace voltage path. Check windings resistance. | |
No electricity power supply. | Check the Power cord is connected and live, and the machine is switched on. | |
Compressor only hums slightly/ briefly. | Check and replace relays. | |
Relays loose. | Check and refit relays. | |
Compressor not working. | Please contact technical support. | |
DC Tank empty. | Check water level and replace level sensor in fill valve as needed. | |
Fan not working. | Check and replace, as necessary. | |
Hot Water not Hot | Hot water mode switched off. | Switch on hot water mode. |
Heating cycle incomplete. | Wait for heating LED to stop showing. | |
Hot water demand too high. | Advise user/s. | |
Hot Thermostat not working. | Replace thermostat. | |
Over heat function active (Heating mode LED not showing while heating mode switch on). | Reset switch on overheat temperature sensor. | |
Hot Water Heater not working. | Replace Hot Water Tank. |
Fault Diagnosis: Water Leaks
Problem/Report | Possible Cause | Suggested Action |
---|---|---|
Water lying on top edge of lower door panel and/or bottom of cabinet. | Overflowing Drip Tray waste container. | Empty Waste Container and check drainpipe is not blocked. |
Water lying in bottom of machine | Level Sensors not working. | Check operation and replace if needed. |
Leak in supply inlet pipe work and/or filter. | Locate and repair accordingly. | |
Leak from machine water pipe work fittings. | Locate and repair accordingly. | |
Check pressure and fit pressure reducing valve if needed. | ||
DC tank overfilling. | Check level control sensor and fill valve function. |
Fault Diagnosis: Miscellaneous
Problem/Report | Possible Cause | Suggested Action |
---|---|---|
No LED Control Lights | No electricity to Machine. | Check power supply and reconnect as necessary (Also check out other symptoms as described separately). |
Check Fuse in IEC Socket. | Replace if necessary. | |
Control PCB not working (Machine working normally otherwise). | Check & replace PCB as necessary. | |
Machine Shakes on Start-up. | Compressor Starting. | No action needed. This is quite normal. |
Level Surface. | ||
Uneven Surface. | Level up machine using adjustable feet. | |
Missing Fixings. | Replace missing fixings. | |
Tripping out Electricity Supply. | Machine in high humidity environment. | Discuss possible repositioning with customer. |
Electrical circuitry faults. | Test, identify and address accordingly. See Electrical Diagrams. | |
Please contact technical support. | ||
No/Inadequate Water Dispenses | Low incoming Water pressure. | Consider re-plumbing to alternative supply if possible or providing a pressure boost system. |
Low/no CO2 Pressure. | Check regulator and/or replace cylinder. | |
Intermittent Water Dispense From Sparkling Water Valve | Trapped air in pipe work (especially where water pressure is low or after filter change). | Hold button on to purge air out. (This could take several minutes where pressure is low). |
Use filter function if available. | ||
Button not being pressed enough. | Press button firmly N.B. This could be caused by a surrounding cold environment making the action stiffer. | |
Control PCB not working. | Check & replace as necessary. | |
Slow but Continuous Water Dispense From Hot Water Valve. | Limescale build-up inside Hot Water Tank/Hot Water Pump/Hot Water Dispense Pipework. | Replace Hot Water Tank/Hot Water Pump/Hot Water Dispense Pipework, as necessary. |
Hot Water Pump not working. | Check & replace as necessary. | |
Intermittent Water Dispense & Hammering Noise | Fluctuating mains water pressure situation. | Contact Technical Support regarding special replacement washers available. |
Continuous Water Dispense | Button jammed on/ not working. | Replace Control PCB and or/ button Panel as needed. |
Debris blocking hole in diaphragm washer. | Dismantle Valve and clean out. | |
Solenoid valve not working. | Check valve and replace if needed. |
Exploded Diagrams
Chilled & Ambient
Part number: | Description: | |
---|---|---|
123155 | Left Top Panel Cover Plate | View in store |
171244 | Faucet LED Assembly - 6B | View in store |
123156 | Right Top Panel Cover Plate | View in store |
145015 | Waste Drain Grill | View in store |
191171 | Chilled & Ambient label | View in store |
191175 | Control Button Membrane Under Liner | View in store |
172144 | IEC Power Cord set - Danish | View in store |
121516 | Side Panel - Right | View in store |
120515 | Door Panel (Shell only) | View in store |
120521 | Door Panel Infill | View in store |
173274 | Leak Detector Probe | View in store |
193165 | Waste Water Container (2 ltr) | View in store |
173277 | Leak Detector Module | View in store |
173267 | Cold Thermostat | View in store |
131426 | 2-Port Drainage Outlet | View in store |
171241 | DC Level Control Board | View in store |
184565 | Cup Dispenser Tube Set | View in store |
171235 | DCA Main Control Board | View in store |
173241 | Solenoid Valve | View in store |
194121 | Grit Filter | View in store |
132448 | 1/4" PF x 1/4" Stem Single Check Valve | View in store |
174352 | Fan | View in store |
184602 | Inner Front Cover | View in store |
174323 | IEC Fuse | View in store |
121515 | Side Panel - Left | View in store |
172231 | Compressor Relay Set | View in store |
123154 | Upper Top Panel | View in store |
174377 | 24vDC PSU | View in store |
175363 | DC Pump | View in store |
145011 | DCA/H Faucet Assembly | View in store |
193187 | Waste Water Container (Optional 10ltr) | View in store |
172148 | IEC Power Cord set - Schuko/EURO | View in store |
172152 | IEC Power Cord set - UK | View in store |
852108 | IEC Power Cord set - Swiss | View in store |
171247 | Faucet LED Assembly - 4B (1404) | View in store |
Chilled, Ambient & Sparkling
Part number: | Description: | |
---|---|---|
171236 | DCAS Main Control Board | View in store |
171242 | DCS Level Control Board | View in store |
132448 | 1/4" PF x 1/4" Stem Single Check Valve | View in store |
131426 | 2-Port Drainage Outlet | View in store |
120515 | Door Panel (Shell only) | View in store |
120521 | Door Panel Infill | View in store |
121515 | Side Panel - Left | View in store |
123155 | Left Top Panel Cover Plate | View in store |
123156 | Right Top Panel Cover Plate | View in store |
145015 | Waste Drain Grill | View in store |
121516 | Side Panel - Right | View in store |
171244 | Faucet LED Assembly - 6B | View in store |
172144 | IEC Power Cord set - Danish | View in store |
173241 | Solenoid Valve | View in store |
173267 | Cold Thermostat | View in store |
173274 | Leak Detector Probe | View in store |
173277 | Leak Detector Module | View in store |
174352 | Fan | View in store |
184565 | Cup Dispenser Tube Set | View in store |
174323 | IEC Fuse | View in store |
193165 | Waste Water Container (2 ltr) | View in store |
194121 | Grit Filter | View in store |
172231 | Compressor Relay Set | View in store |
191173 | S42 DCAS Control Button Membrane | View in store |
191175 | Control Button Membrane Under Liner | View in store |
184602 | Inner Front Cover | View in store |
123154 | Upper Top Panel | View in store |
174377 | 24vDC PSU | View in store |
174385 | 48vDC Carbonation Pump PSU | View in store |
175363 | DC Pump | View in store |
174380 | 48vDC Carbonation Pump | View in store |
145012 | DCAS Faucet Assembly | View in store |
193187 | Waste Water Container (Optional 10ltr) | View in store |
172148 | IEC Power Cord set - Schuko/EURO | View in store |
172152 | IEC Power Cord set - UK | View in store |
852108 | IEC Power Cord set - Swiss | View in store |
171247 | Faucet LED Assembly - 4B (?1404) | View in store |
Chilled, Ambient & Hot
Part number: | Description: | |
---|---|---|
171239 | DCAH Main Control Board | View in store |
171243 | DCH Level Control Board | View in store |
171244 | Faucet LED Assembly - 6B | View in store |
132448 | 1/4" PF x 1/4" Stem Single Check Valve | View in store |
131426 | 2-Port Drainage Outlet | View in store |
120515 | Door Panel (Shell only) | View in store |
120521 | Door Panel Infill | View in store |
121515 | Side Panel - Left | View in store |
123155 | Left Top Panel Cover Plate | View in store |
123156 | Right Top Panel Cover Plate | View in store |
145015 | Waste Drain Grill | View in store |
121516 | Side Panel - Right | View in store |
171244 | Faucet LED Assembly - 6B | View in store |
172144 | IEC Power Cord set - Danish | View in store |
173241 | Solenoid Valve | View in store |
173267 | Cold Thermostat | View in store |
173274 | Leak Detector Probe | View in store |
173277 | Leak Detector Module | View in store |
174352 | Fan | View in store |
184565 | Cup Dispenser Tube Set | View in store |
174323 | IEC Fuse | View in store |
193165 | Waste Water Container (2 ltr) | View in store |
172231 | Compressor Relay Set | View in store |
166982 | Hot Water Tank | View in store |
174370 | Hot Water Pump Assembly | View in store |
173265 | 92C Temperature Sensor | View in store |
173255 | 105C Safety Temperature Cut-out Sensor | View in store |
191173 | S42 DCAS Control Button Membrane | View in store |
191175 | Control Button Membrane Under Liner | View in store |
194121 | Grit Filter | View in store |
184602 | Inner Front Cover | View in store |
123154 | Upper Top Panel | View in store |
174377 | 24vDC PSU | View in store |
175363 | DC Pump | View in store |
191174 | DCHS Control Button Membrane | View in store |
193187 | Waste Water Container (Optional 10ltr) | View in store |
172148 | IEC Power Cord set - Schuko/EURO | View in store |
172152 | IEC Power Cord set - UK | View in store |
852108 | IEC Power Cord set - Swiss | View in store |
171247 | Faucet LED Assembly - 4B (?1404) | View in store |
Chilled, Hot & Sparkling
Part number: | Description: | |
---|---|---|
171240 | DCHS Main Control Board | View in store |
171242 | DCS Level Control Board | View in store |
171244 | Faucet LED Assembly - 6B | View in store |
131426 | 2-Port Drainage Outlet | View in store |
121515 | Side Panel - Left | View in store |
123155 | Left Top Panel Cover Plate | View in store |
123156 | Right Top Panel Cover Plate | View in store |
145015 | Waste Drain Grill | View in store |
171249 | H Level Control Board | View in store |
171244 | Faucet LED Assembly - 6B | View in store |
172144 | IEC Power Cord set - Danish | View in store |
173241 | Solenoid Valve | View in store |
173267 | Cold Thermostat | View in store |
174352 | Fan | View in store |
184565 | Cup Dispenser Tube Set | View in store |
174323 | IEC Fuse | View in store |
194121 | Grit Filter | View in store |
172231 | Compressor Relay Set | View in store |
166982 | Hot Water Tank | View in store |
174370 | Hot Water Pump Assembly | View in store |
173265 | 92C Temperature Sensor | View in store |
173255 | 105C Safety Temperature Cut-out Sensor | View in store |
191174 | DCHS Control Button Membrane | View in store |
191175 | Control Button Membrane Under Liner | View in store |
120515 | Door Panel (Shell only) | View in store |
120521 | Door Panel Infill | View in store |
173274 | Leak Detector Probe | View in store |
193165 | Waste Water Container (2 ltr) | View in store |
173277 | Leak Detector Module | View in store |
132448 | 1/4" PF x 1/4" Stem Single Check Valve | View in store |
121516 | Side Panel - Right | View in store |
123154 | Upper Top Panel | View in store |
174377 | 24vDC PSU | View in store |
175363 | DC Pump | View in store |
174385 | 48vDC Carbonation Pump PSU | View in store |
174380 | 48vDC Carbonation Pump | View in store |
184602 | Inner Front Cover | View in store |
171247 | Faucet LED Assembly - 4B (?1404) | View in store |
172148 | IEC Power Cord set - Schuko/EURO | View in store |
172152 | IEC Power Cord set - UK | View in store |
852108 | IEC Power Cord set - Swiss | View in store |
145013 | DCHS Faucet Assembly | View in store |
193187 | Waste Water Container (Optional 10ltr) | View in store |
Technical Information
Chilled & Ambient Electrical Circuit Diagram
Chilled, Ambient & Sparkling Electrical Circuit Diagram
Chilled, Ambient & Hot Electrical Circuit Diagram
Chilled, Hot & Sparkling Electrical Circuit Diagram
Chilled & Ambient Water Pathway Diagram
Chilled, Ambient & Sparkling Water Pathway Diagram
Chilled, Ambient & Hot Water Pathway Diagram
Chilled, Hot & Sparkling Water Pathway Diagram
Specification
COOLING SYSTEM | All Models | High efficiency compression system with capillary control. Premium quality long life hermetic compressor. Compact internal condenser – fan assisted for greater efficiency. Environmentally friendly R600 refrigerant. 3.5 litre insulated stainless steel chiller tank with level control containing stainless steel cold water direct chill coil. Thermostatically controlled chilled water temperature. Stainless steel carbonator tank with independent level control fitted inside coil. High capacity, low voltage diaphragm inlet pump. |
HEATING SYSTEM | Chilled, Ambient & Hot | High efficiency compression system with capillary control. Premium quality long life hermetic compressor. Compact internal condenser – fan assisted for greater efficiency. Environmentally friendly R600 refrigerant. 3.5 litre insulated stainless steel chiller tank with level control containing stainless steel cold water direct chill coil. Thermostatically controlled chilled water temperature. 1.75lt stainless steel hot water tank with thermostatic temperature control (92C max), insulated for energy conservation. |
Chilled, Hot & Sparkling | High efficiency compression system with capillary control. Premium quality long life hermetic compressor. Compact internal condenser – fan assisted for greater efficiency. Environmentally friendly R600 refrigerant. 3.5 litre insulated stainless steel chiller tank with level control containing stainless steel cold water direct chill coil. Thermostatically controlled chilled water temperature. Stainless steel carbonator tank with independent level control fitted inside coil and high capacity, low voltage diaphragm inlet pump.1.75lt stainless steel hot water tank with thermostatic temperature control (92C max), insulated for energy conservation. | |
COLD TEMPRATURE | 2°C to 11°C | |
HOT TEMPRATURE | 92°C Max | |
THROUGHPUT PER HOUR | 18 litres cold < 12°C / 16 litres sparkling <12°C | |
DISPENSE | Ergonomically designed and situated light touch sensitive controls. | |
MAXIMUM RUNNING POWER CONSUMPTION | Chilled & Ambient | 100 watt |
Chilled, Ambient & Sparkling | 140 watt | |
Chilled, Ambient & Hot | 900 watt | |
Chilled, Hot & Sparkling | 940 watt | |
POWER SUPPLY | IEC power socket. | |
WATER CONNECTION | 1/4 inch quick connection. | |
C02 CONNECTION | 1/4 inch quick connection. | |
COUNTERTOP DIMENSIONS | (w x d x h) 520 x 410 x 1010mm | |
WEIGHTS | Chilled & Ambient | 27.0kg |
Chilled, Ambient & Sparkling | 30.9kg | |
Chilled, Ambient & Hot | 27.8kg | |
Chilled, Hot & Sparkling | 31.6kg |